I. General

HZJB-D Single Phase Relay Protection Tester is a portable field testing

equipment with excellent performance; Elegance and polished appearance with aluminum

alloy chassis and PC panel, within the ARM chip control, LCD screen display voltage and

current output stopwatch, it could output a full isolation way for adjustable AC/DC voltage,

and AC/DC current and a way for adjustable DC voltage; the output loop with double

overload protection with large output capacity ,small volume, light weight, high reliability ,It

Suitable for field calibration and test for various relay.

II. Main Features

1.Output a full isolation way for adjustable DC voltage, Automatic protection for short

circuit, overload and out range.

2.Maximum Output Current:0~150A.

3.Equipped with LCD digital AC/DC volt-ampere meter, can show the AC and DC voltage

and current values, stopwatch, potential, contact state.

4.Internal electric stopwatch; Available electrical contacts, maximum potential

250V;

Dual channel measurement.

5.Light-weight design, small-volume, and fully-functional.

III. Main Technical Parameter And Functions

1.Rated input power: AC:220V±10%·1000VA·50Hz

2.AC Output

Range(A)

No-load Voltage

(Minimum)V

Full-load Voltage

(Minimum)V

Full-load Current

(Maximum)A

0~10

90

80

10

0~40

25

22

40

0~100

10

8

150

Range(V)

No-load Voltage

(Minimum)V

Full-load Voltage

(Minimum)V

Full-load Current

(Maximum)A

0~250(AC)

250

240

3

Summary of Contents for HZJB-D

Page 1: ...HZJB D Single Phase Relay Protection Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...nual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this in...

Page 3: ...Contents I General 1 II Main Features 1 III Main Technical Parameter And Functions 1 IV Panel And Function Instruction 3 V Usage Method 5 VI Caution 7 VII Packing List 7...

Page 4: ...es 1 Output a full isolation way for adjustable DC voltage Automatic protection for short circuit overload and out range 2 Maximum Output Current 0 150A 3 Equipped with LCD digital AC DC volt ampere m...

Page 5: ...0 000 6 000A AC or DC Accuracy 0 5 Measurement methods AC True RMS value DC Average 6 Voltmeter Range 0 0 600 0V AC OR DC Accuracy 0 5 Measurement methods AC True RMS value DC Average 7 Resistors and...

Page 6: ...tial Contact Reset for time reset check if the stopwatch reset to zero before counting each time Single Dual Channel for choosing stopwatch status On default external dual channel Press and hold more...

Page 7: ...ng into the voltage and current output grade 2 Capacitor 10uF AC450V 4 Measure selection indicate 0 100A 0 40A 0 10A 0 250V 0 300V external input Led Indicator Lights Up shows output value in LCD 5 Sp...

Page 8: ...voltage and current output 2 Auxiliary Output DC voltage and current First cycles the potentiometer to zero connect the output line select the required voltage value 0V or 110 220V then press output b...

Page 9: ...ot charged or charged contact switch signal Figures 1 1 4 are shown Note Regardless of the figure 1 3 4 connection way the black terminal of stopwatch should always connect to LOW level 3 Application...

Page 10: ...eep safety 2 Please adjust the contrast adjustment if the display shows dark or black 3 The measuring selection button is invalid after the current outputting VII Packing List No Item Qty 1 Main engin...

Reviews: