Precautions
Before connecting cables, ensure that the input and output circuit breakers in the
SmartACBox as well as all the switches connecting to the SmartACBox are OFF. Otherwise,
the high voltage of the SmartACBox may result in electric shocks.
Huawei shall not be liable for any device damage caused by violation of the cable
connection regulations specified in this document.
Only certified electricians are allowed to connect cables.
Ware proper PPE at all time when connecting cables.
The cable colors shown in cable connection diagrams are for reference only. Select cables according to
local cable specifications.
5.1 Cable Specifications
No. Cable
Recommended Model
or Specifications
Cross-sectional Area
Range of the Cable
Cable
Source
1
AC input
power cable
Three-core outdoor
armored copper cable
with an OT-M5 terminal
3.5–8 mm
2
Prepared
by the
customer
2
AC output
power cable
Three-core outdoor
armored copper cable
with an OT-M12
terminal
150–200 mm
2
Prepared
by the
customer