Check the Health Status of the Switch
5
Log in to the switch and
run the
display health
command to check the health status of the switch
.
1
View the voltage information and check whether the voltage status of each present card is normal.
2
View the temperature information and check whether the temperature status of each present card is
normal.
3
View the power information and check whether the status of each present power supply is Supply.
-------------------------------------------------------------------------------
Slot Card SDR No. SensorName
Status Upper Lower Voltage.(V)
-------------------------------------------------------------------------------
7 -
3
3.3V
normal 3.9592 2.6460 3.2928
-
4
2.5V
normal 2.9988 1.9992 2.5872
-
5
1.8V
normal 2.1560 1.4406 1.8816
If the voltage status of a card is abnormal, record the fault information and handle the fault according
to
the
Troubleshooting Guide
. If the fault cannot be rectified, contact your agent or Huawei enterprise
technical support hotline.
-----------------------------------------------------------
Slot Card SDR No. Status Upper Lower Temperature.(C)
-----------------------------------------------------------
7 -
1
normal 67.00 0.00 38.00
-
2
normal 64.00 0.00 34.00
10 -
1
normal 58.00 0.00 36.00
-
2
normal 56.00 0.00 31.00
If the temperature is abnormal, check whether the ambient temperature in the equipment room is
normal, whether the heat dissipation channel in the chassis is blocked, and whether all fan modules
are working properly. Take appropriate measures accordingly. If the fault cannot be rectified, record
the fault information and contact your agent or Huawei enterprise technical support hotline.
--------------------------------------------------------------------------
PowerNo Present Mode State
Current(A) Voltage(V) RealPwr(W)
--------------------------------------------------------------------------
PWR1
YES AC
Supply
2.7500
53.5200 148.6000
PWR2
YES AC
Supply
2.6400
53.3900 143.6000
PWR3
NO N/A
N/A
N/A
N/A
N/A
PWR4
NO N/A
N/A
N/A
N/A
N/A
PWR5
NO N/A
N/A
N/A
N/A
N/A
PWR6
NO N/A
N/A
N/A
N/A
N/A
If the power status is abnormal, check whether the power supply is switched on and whether the
power cable is loose, and replace the problematic power supply. If the fault cannot be rectified, record
the fault information and contact your agent or Huawei enterprise technical support hotline.
View the fan information and check whether the register status of each fan is YES.
4