Figure 1-47
Metal contact strips of the same height
Step 2
Hold an RJ45 connector and turn it by 45°. Observe the top edges of the metal contact strips.
Figure 1-48
shows an unqualified piece.
Figure 1-48
Unparallel metal contact strips of different heights
Step 3
Check whether the metal contact strips are clean. If they are not clean and the dirt cannot be
removed, replace it with a new RJ45 connector.
Figure 1-49
shows an unqualified piece.
Figure 1-49
Dirt on a metal contract strip
Step 4
Check whether the metal contact strips and the plastic septa are well aligned and intact. If a
part is skewed and it cannot be fixed, replace it with a new RJ45 connector.
Figure 1-50
shows an unqualified piece.