
Figure 8-43
Securing the captive screw into the connection hole
----End
8.6 Installing an RRU on an IFS06
This section describes the procedure and precautions for installing an RRU on an IFS06.
Prerequisites
The hoist clamp on the main bracket is secured properly.
NOTICE
l
Do not stand the RRU upright because the RF ports cannot support the weight of the RRU.
l
Place a foam pad or cardboard under the RRU to protect the RRU housing from damage
during the installation.
Context
l
The upper and lower adjustable beams on an IFS06 can be moved up and down to fit for
heights of RRUs.
l
RRUs can be installed on an IFS06 only when the ambient temperature is higher than or
equal to the lowest working temperature of the RRU and at least 5°C (41°F) lower than
the highest working temperature of the RRU. In this scenario, the IFS06 supports at least
three RRUs. When the ambient temperature is higher than or equal to the lowest working
temperature of the RRU and at least 10°C (50°F) lower than the highest working
temperature of the RRU, the IFS06 supports a maximum of six RRUs.
RRU3260
Installation Guide
8 Installing the RRU
Issue 10 (2015-12-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
78