3.4 Installation Scenarios
An RRU can be installed on a pole, U-steel, angle steel, wall, or IFS06. Installation scenarios
must meet heat-dissipation and waterproofing requirements of the RRU.
Requirements for the Installation Scenarios
Application scenarios:
To ensure proper heat dissipation of the RRU, the following requirements must be met:
l
The RRU cannot be installed in an enclosed cabinet without a cooling system.
l
The RRU cannot be installed in an enclosed camouflage box.
l
The RRU cannot be installed in an enclosed equipment room without a cooling system.
l
When multiple RRUs are installed in centralized mode, the minimum clearance
requirements must be met. For details about the minimum clearance requirements, see
3.5.2 Clearances for Three or More RRUs
3.5.3 Installation Spacing Between
l
RRU mounting kits in assembled installation mode are not allowed in indoor scenarios.
NOTICE
If the RRU is improperly installed, heat dissipation of the RRU deteriorates and the RRU may
not work properly, as shown in
Figure 3-6
Improperly installed RRUs
Method of installation:
l
The installation supports' specifications described in this document are only based on the
exterior and dimensions of the mounting kits. Before installing equipment, assess the
strength and reliability of the installation support to determine whether it can bear the
weight of the equipment.
RRU3260
Installation Guide
3 Information About the Installation
Issue 10 (2015-12-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
16