Parameter
Description
Port Number
This parameter indicates the number of an FC host port.
l
If the type of host port module is 2*FC, the port number is
x0
and
x1
(
x
indicates the host port module ID).
l
If the type of host port module is 4*FC, the port number is
x0
,
x1
,
x2
, and
x3
(
x
indicates the host port module ID).
WWPN
The world-wide name of a port. It uniquely identifies a port.
Type
This parameter indicates the type of the FC host port.
Rate (G)
This parameter indicates the data transmission rate of the FC host port.
l
If each host port module consists of 4*FC, the options will be changed with
the product type:
–
S5300
:
1 Gbit/s
,
2 Gbit/s
,
4 Gbit/s
, and
Auto
.
–
S5500
:
2 Gbit/s
and
4 Gbit/s
.
–
S5600
:
2 Gbit/s
and
4 Gbit/s
.
–
S6800E
:
1 Gbit/s
,
2 Gbit/s
,
4 Gbit/s
, and
Auto
.
there are two options:
2 Gbit/s
and
4 Gbit/s
.
l
If the host port module consists of 2*FC, there are four options:
1 Gbit/s
,
2 Gbit/s
,
4 Gbit/s
, and
Auto
.
Port Mode
This parameter indicates the mode of the FC host port, including
Fabric
,
Arbitrated Loop
and
Point to Point
.
----End
Exception Handling
If an alarm that is related to the FC host port is displayed on the alarm interface, handle it by
referring to the suggestion in the alarm items.
If the fault persists, contact the technical support engineers.
5.9 Browsing Current Alarms
This section describes how to browse current alarms through the OSM.
Reference Standard
User can browse current alarms in the operation interface.
Precaution
The current alarms include the current fault and the current event.
By creating the Trap IP through the
Configuration Operation
of the OSM, the S5000 storage
system can send the Trap alarms to the network management system. These alarms can be
permanently stored even at the time of power failure.
5 Routine Maintenance Guide of the OSM
OceanStor S5000 Series Storage System
Routine Maintenance
5-14
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-04-20)