NOTE
The eth number of the GE service port on controller A correponds to that of the GE service port on
controler B, namely, the eth number of the GE service port in the same position on controller A and
controller B is the same. As shown in
, the eth number of the GE
service port in the same row is the same.
l
Interface Card ID 1 and 2
–
When either the interface card whose ID is 1 or 2 holds the GE port module, the eth
number of the GE service port on controller A correponds to that of the GE service port
on controler B, as shown in
. When configuring data replication through the
GE service ports, you need to set the IP addresses of the GE service ports with the same
eth number in the same network segment.
Table 7-2
Corresponidng relation of the eth number in the interface card whose ID is
1 or 2
Controller A
Controller B
10/20
10/20
11/21
11/21
12/22
12/22
13/23
13/23
–
When the interface card whose ID is 1 and 2 both hold the GE port module, the eth
number of the GE service port on controller A doesn't correpond to that of the GE service
port on controler B, as shown in
. When configuring data replication through
the GE service ports, you need to set the IP addresses of the GE service ports with the
same eth number in the same network segment.
Table 7-3
Corresponidng relation of the eth number in the interface card whose ID is
1 and 2
Controller A
Controller B
10
20
11
21
12
22
13
23
20
10
21
11
22
12
23
13
Before creating a replicate volume group, complete the following operations.
OceanStor VIS6000 Series Virtual Intelligent Storage
System
Initial Configuration Guide
7 Configuring the Data Replication Function
Issue 08 (2010-05-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7-3