Figure 1-1
HyperMetro solution network topology
Data center A
Data center B
Local storage array
Quorum server
Fibre Channel switch
Ethernet switch
Remote storage array
Host-to-storage network
Host cluster
FC
HyperMetro replication
network
Same-city cross-DC
network
Quorum network
Quorum site
Ethernet switch
Ethernet switch
Fibre Channel
switch
Fibre Channel
switch
Fibre Channel switch
IP
Ethernet switch
Ethernet switch
Ethernet switch
IP
Host cluster
To ensure reliability of storage arrays, establish redundant links among the network between
hosts and storage arrays, HyperMetro replication network, same-city network between data
centers, and quorum network.
Table 1-2
Network overview
Network
Description
Network of hosts and
storage systems
All hosts in the two data
centers can form a
cluster and host
networks can
interconnect across data
centers.
Network
type
Supports GE and 10GE networks.
Networking
mode
l
A fully interconnected network is used
between hosts and storage systems, that is,
each service host is physically and logically
connected to two HyperMetro storage
arrays.
l
Dual-switch networking is required.
l
The HyperMetro replication network,
storage-to-host network, and quorum
network need to be physically isolated and
common ports are not recommended on
storage devices.
OceanStor V3 Series
HyperMetro Feature Guide for File
1 Feature Description
Issue 05 (2018-01-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6