13.2 LED Setting Operations
13.2.1
Reference Process
Command
Description
AT^LEDCTRL=?
Check the parameter range supported by
the command.
^LEDCTRL: (0-2),00003FFF,(0-1),(1-100),(1-100),(1-100),(1-100)
OK
AT^LEDCTRL?
Query the current LED program,
1
indicates adapting HUAWEI default
program.
^LEDCTRL: 1
OK
AT^LEDCTRL=0
Turn off LED function.
OK
AT^LEDCTRL=1
Configure HUAWEI default program.
OK
AT^LEDCTRL=2,00000001,0
Configure that offline state LED mode is
Permanently off.
OK
AT^LEDCTRL=2,00000001,1,10,10
Configure that offline state LED mode is
single flash and cycle time is 2s (1s on/1s
off).
OK
AT^LEDCTRL=2,00000001,1,1,1,1,17
Configure that offline state LED mode is
double flash and cycle time is 2s (0.1s
on/0.1s off/0.1s on/1.7s off).
OK
AT^LEDCTRL=2,0000000F,1,1,1,1,17
Configure that offline, power on
initialization, register fail no service and
connect to no service state LED mode
are double flash. Cycle time is 2s (0.1s
on/0.1s off/0.1s on/1.7s off).
OK
AT^LEDCTRL=2,00007000,1
Configure that register successful on
LTE, connect and transmit state LED
mode are Permanently on.