HUAWEI ME909s Series LTE Mini PCIe Module
Hardware Guide
Electrical and Reliability Features
Issue 02 (2016-09-07)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
47
Description
Bands
Test Value (Unit: mA) Notes/Configuration
Typical
Idle
LTE
LTE bands
51
Module is powered up.
DRX cycle=8 (2.56s)
Module is registered on the
network.
USB is in active.
HSPA+/WCDMA UMTS bands
55
Module is powered up.
DRX cycle=7 (1.28s)
Module is registered on the
network, no data is transmitted.
USB is in active.
GPRS/EDGE
GSM bands
56
Module is powered up.
MFRMS=5 (1.175s)
Module is registered on the
network, no data is transmitted.
USB is in active.
Table 5-7
Averaged Data Transmission DC power consumption of ME909s-821 Mini
PCIe module (HSPA/WCDMA/TD-SCDMA/LTE)
Description
Band
Test Value Units
Power (Unit: dBm)
WCDMA
Band 1
(IMT2100)
226
mA
0 dBm Tx Power
308
10 dBm Tx Power
830
23.5 dBm Tx Power
Band 9
(J1700)
220
mA
0 dBm Tx Power
257
10 dBm Tx Power
511
23.5 dBm Tx Power
Band 5
(850 MHz)
220
mA
0 dBm Tx Power
257
10 dBm Tx Power
511
23.5 dBm Tx Power
Band 8
(900 MHz)
221
mA
0 dBm Tx Power
258
10 dBm Tx Power
541
23.5 dBm Tx Power
HSDPA
Band 1
(IMT2100)
186
mA
0 dBm Tx Power
227
10 dBm Tx Power