For details, see the following table.
Bracket to Be
Adjusted
Parameter to Be Adjusted
Default value
(dB)
ATT5
Level of CATV signals. (Main)
0
ATT4
Level of combined CATV and downstream
DOCSIS signals.(Main)
0
ATT0
Level of combined CATV and downstream
DOCSIS signal of the RF OUT0.
4
ATT1
Level of combined CATV and downstream
DOCSIS signal of the RF OUT1.
4
ATT2
Level of combined CATV and downstream
DOCSIS signal of the RF OUT2.
4
ATT3
Level of combined CATV and downstream
DOCSIS signal of the RF OUT3.
4
No.
Test point
Function
TP.1
Tests level of the RF OUT0
port signal.
TP.8
Tests level of the RF OUT1
port signal.
TP.9
Tests level of the RF OUT2
port signal.
MA5833-DD60
Hardware Commissioning Guide
5 Adjusting the Signal Level
Issue 01 (2018-12-26)
Copyright © Huawei Technologies Co., Ltd.
10