Forced Charge and Discharge
Step 1 Choose Maintenance > Battery maintenance > Forced charge and discharge,
set forced charged and discharged parameters, and tap Submit.
Figure 6-6 Forced Charge and Discharge
Table 6-3 Description of forced charge/discharge parameters
Parameter
Description
Value Range
Charge/Discharge
Specifies whether to
charge or discharge the
battery.
● Stop
● Charge
● Discharge
Charge/Discharge power
(kW)
Specifies the forced
charge/discharge power.
● Charge: [0, Maximum
charge power]
● Discharge: [0,
Maximum discharge
power]
Charge/Discharge setting
mode
Set the charge and
discharge mode.
● Duration
● Charged/Discharged
energy
Charge/Discharge
duration (min)
Sets the charge and
discharge duration.
[0, 1440]
Remaining charge/
discharge duration (min)
Indicates the remaining
charge and discharge
duration. This parameter
cannot be set.
-
Charged/Discharged
energy (kWh)
Indicates the charged or
discharged battery level.
This parameter cannot
be set.
-
LUNA2000-(5-30)-S0
User Manual
6 System Commissioning
Issue 01 (2020-10-20)
Copyright © Huawei Technologies Co., Ltd.
71