Step 4 Modify the IP address for the IVS1800.
1. Choose Local Configuration > Server configuration. Set the service IP
address (internal IP address of the IVS1800), time zone, and time according to
the site requirements.
Figure 4-25 Configuring the server (Single Mode by default)
NO TE
Set Business IP to XXX.XXX.XXX.XXX, Subnet mask to 255.255.255.0, and Gateway IP
to XXX.XXX.XXX.XXX. The values here are examples. The actual value prevails.
2. Change the PC IP address to an address in the network segment of the new
IVS1800 IP address, enter the IVS1800 IP address in the address box of the
Internet browser, and log in to the OMU portal system.
3. (Optional) Configure the NTP synchronization. After setting The NTP clock
source server to Yes, set the IP address of the NTP server.
NO TE
Currently, the IVS1800 and NTP source server must be in the same LAN for NTP
synchronization. For details, see
.
If the IVS1800 and the NTP source server are not in the same LAN, you need to
manually set the time as follows: Choose Local Configuration > Server configuration
and change Timezone config and Time config based on the time of the source server
to be synchronized.
4. Choose Maintenance > Unified Configuration, set Module Name to MU,
and click Search.
5. In the search result, click Edit in the row where the value of Parameter Name
is MUNNatIP and set Value to the external IP address of the IVS1800. Click
Save.
IVS1800 Video Management System
User Manual
4 Commissioning the IVS1800
Issue 02 (2021-01-27)
Copyright © Huawei Technologies Co., Ltd.
44