3
1 Drilling the Installation Holes
a
2 Leading in, Stripping, Securingand Coiling Distribution Cable
Remove the velcro strap and transparent cover on the splicing tray, then turn over the splicing trays and fiber distribution
panel.
•
The maximum turnover angle of fiber distribution panel is 120
°
.
•
The maximum turnover angle of splicing tray is 90
°
.
Velcro strap Transparent cover
Open the cap, use the key to unlock the FAT, hold the key, open the buckle w ith your hands, unbuckle the FAT, and open
the FAT cover.
Opening the Case
b
Splicing trays
Fiber distribution panel
Lead in the distribution cable through the cable hole on the sealing block
.
Determine the length to be stripped from the optical cable, mark the position to be stripped, and strip the optical cable.
Cap
Key
Unit: mm
70 to 100
Aramid fiber
1800
Distribution cable
Bare fiber
Loose tube
210