background image

About This Document

Purpose

The white paper of the CX116 GE pass through module of the E9000 server describes the
CX116 in terms of the functions, appearance, ports, physical structure, logical structure,
technical specifications, and certifications. You can learn about the CX116 by reading this
document.

Intended Audience

This document is intended for:

l

Huawei presales engineers

l

Channel partner presales engineers

l

Huawei enterprise presales engineers

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol

Description

DANGER

Indicates a hazard with a high level or medium level of
risk which, if not avoided, could result in death or serious
injury.

WARNING

Indicates a hazard with a low level of risk which, if not
avoided, could result in minor or moderate injury.

CAUTION

Indicates a potentially hazardous situation that, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.

TIP

Indicates a tip that may help you solve a problem or save
time.

NOTE

Provides additional information to emphasize or
supplement important points in the main text.

 

Huawei CX116 Pass Through Module
White Paper

About This Document

Issue 05 (2017-03-27)

Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

ii

Summary of Contents for CX116

Page 1: ...Huawei CX116 Pass Through Module V100R001 White Paper Issue 05 Date 2017 03 27 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...cument may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this d...

Page 3: ... Description DANGER Indicates a hazard with a high level or medium level of risk which if not avoided could result in death or serious injury WARNING Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury CAUTION Indicates a potentially hazardous situation that if not avoided could result in equipment damage data loss performance deterioration or ...

Page 4: ...ion Added Added the description about the working temperature s compliance with the ASHRAE Class A3 standard in 1 8 Technical Specifications Issue 02 2016 08 20 This issue is the second official release Mode Change Description Delete d Deleted the Hardware Structure and Architecture sections Deleted some international standards and protocols in 2 2 Certifications Issue 01 2015 11 03 This issue is ...

Page 5: ...e Structure 8 1 6 Architecture 10 1 7 Compatibility 11 1 8 Technical Specifications 11 2 Standards and Certifications 13 2 1 Standards Compliance 14 2 2 Certifications 14 Huawei CX116 Pass Through Module White Paper Contents Issue 05 2017 03 27 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd iv ...

Page 6: ...n the CX116 1 5 Hardware Structure This topic describes the components mainboard layout and connectors of the CX116 1 6 Architecture This topic describes the CX116 logical architecture 1 7 Compatibility This topic describes mezz modules that can work with the CX116 and cables supported by ports on the CX116 panel 1 8 Technical Specifications This topic describes the CX116 technical specifications ...

Page 7: ...vides a maximum of 32 gigabit Ethernet GE ports 1 2 Appearance This topic describes the CX116 in terms of its appearance panel and installation positions in the chassis CX116 Figure 1 1 shows the CX116 Figure 1 1 Appearance Installation Positions The CX116 is installed in a rear slot of the E9000 chassis Figure 1 2 shows the positions and slot numbers for installing the CX116s in a chassis Huawei ...

Page 8: ...switch modules For ease of cable routing and maintenance you are advised to install the CX116 in slot 1E or 4E Panel Figure 1 3 shows the CX116 panel Huawei CX116 Pass Through Module White Paper 1 Overview Issue 05 2017 03 27 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3 ...

Page 9: ...r 10 Captive screw NOTE The numbers on the left side are port serial numbers The arrow direction of a triangle indicates the direction of a port ESNs An Equipment Serial Number ESN is a string that uniquely identifies a server An ESN is required when you apply for technical support from Huawei Figure 1 4 shows the ESN format Huawei CX116 Pass Through Module White Paper 1 Overview Issue 05 2017 03 ...

Page 10: ...icate October to December 5 Indicates the sequence number six digits 6 Indicates RoHS compliance one character 7 Indicates the internal model number of the board 1 3 Ports This topic describes the ports on the CX116 Overview Table 1 1 describes the ports on the CX116 Table 1 1 Ports Port Type Quantity Description GE electric al port RJ45 32 The panel provides four 2 4 RJ45 connectors Each CX116 pr...

Page 11: ...ely A physical number is in slot number port number format Physical numbers are used for locating ports when you connect network cables and view the mapping between the ports on the pass through module and the server slots The 16 front half width slots of the E9000 server are numbered 1 to 16 Each slot has two ports slot number 1 and slot number 2 For example half width slot 7 has ports 7 1 and 7 ...

Page 12: ...2 GE Slot n 1 GE Slot n 2 GE Port Mapping Between the CX116 and the MZ111 The MZ111 provides four GE ports including ports 1 2 3 and 4 Ports 1 and 3 map to the CX116 in slot 1E and ports 2 and 4 map to the CX116 of the in slot 4E as shown in Figure 1 7 Figure 1 7 Port mapping Slot n 1 GE CX116 in 1E CX116 in 4E Port 1 GE MZ111 in Mezz2 Port 4 GE Port 2 GE Port 3 GE Slot n 2 GE Slot n 1 GE Slot n 2...

Page 13: ...fficult to distinguish a blinking frequency of 4 Hz from a blinking frequency of 5 Hz When the HLY indicator is quickly blinking red you are advised to check whether the device is securely inserted and then check whether a critical alarm is generated GE electrical port status indicator Connection and data transmission status indicator for an Ethernet electrical port Green l Off The port is not con...

Page 14: ...connector Provides signal channels for the CX116 and other slots 2 Positioning pin Positions the CX116 in the slot 3 Midplane power connector Supplies power to the CX116 4 PHY module Converts 32 Serdes signals to 32 1000 Base T Ethernet electric signals that are transmitted to the 32 GE ports on the CX116 panel The CX116 CPLD manages the four PHY modules over the MIIM interfaces Huawei CX116 Pass ...

Page 15: ...h module l Processor module The processor module in a dominant frequency of 333 MHz is the controlling core for the CX116 and supports master slave and multi master modes l CPLD module The CPLD module is a key module to help the processors to collect the CX116 information and power on power off and reset the CX116 l PHY module The PHY module converts the 32 Serdes signals to 32 x 1000 BASE T signa...

Page 16: ... GE dual chip NIC Network Interface Card mezzanine card Supported Cables Table 1 5 Supported cables Module Cable Description Cat 5 unshielded twisted pair UTP cable Category 5 UTP cables that support RJ45 ports Cat 5e UTP cable Category 5e Category 5 enhanced UTP cables that support RJ45 ports Note The table is for reference only For details about the components that can be purchased consult the l...

Page 17: ...h Humidity l Operating humidity 5 RH to 85 RH non condensing l Storage humidity 5 RH to 95 RH non condensing l Long term storage humidity 30 RH to 69 RH non condensing Altitude At an altitude of 900 m 2952 72 ft the highest operating temperature is 40 C 104 F When the device is used at an altitude of 900 m to 5000 m the highest operating temperature decreases by 1 C 1 8 F as the altitude increases...

Page 18: ...al standards and communication protocols that the CX116 complies with 2 2 Certifications This topic describes the certifications that the E9000 has passed Huawei CX116 Pass Through Module White Paper 2 Standards and Certifications Issue 05 2017 03 27 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 13 ...

Page 19: ...ion ECMA TR 70 Environmental protection EN60950 Safety Europe GR 929 Reliability IEC 812 Procedure for Failure Mode and Effects Analysis FMEA IEC 863 Reliability maintainability and availability compliance standard IEC60950 Safety IEC60825 1 2 6 Safety IEC60215 Safety Telcordia SR 332 Reliability IEC61000 EMC standard UL60950 Safety North America 2 2 Certifications This topic describes the certifi...

Page 20: ...009 America UL UL 60950 1 America FCC FCC Part 15 Class A America NTRL UL UL 60950 1 2nd Edition 2011 12 19 Information Technology Equipment Safety Part 1 General Requirements CSA C22 2 No 60950 1 07 2nd Edition 2011 12 Information Technology Equipment Safety Part 1 General Requirements Canada IC ICES 003 Class A Nigeria SONCAP IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 ...