By observing the indicators, you can determine the current operating status of the CX116.
Table 1-2
Indicators
Indicator
Meaning
Color
Description
PWR indicator
Power indicator
Green
l
Off: The module is not
powered on.
l
Blinking green: The
module is being powered
on.
l
Steady green: The module
is working properly.
HLY indicator
Healthy indicator
Red and
green
l
Off: The module is not
powered on.
l
Steady green: The module
is working properly.
l
Blinking red (1 Hz): A
major alarm is generated.
l
Blinking red (4 Hz): A
critical alarm is generated.
l
Blinking red (5 Hz): The
CX116 is not installed
properly.
NOTE
It is difficult to distinguish a
blinking frequency of 4 Hz from
a blinking frequency of 5 Hz.
When the HLY indicator is
quickly blinking red, you are
advised to check whether the
device is securely inserted and
then check whether a critical
alarm is generated.
GE electrical port
status indicator
Connection and
data transmission
status indicator
for an Ethernet
electrical port
Green
l
Off: The port is not
connected or not properly
connected.
l
Blinking green: Data is
being sent or received over
the port.
l
Steady green: The port is
properly connected.
1.5 Hardware Structure
This topic describes the components, mainboard layout, and connectors of the CX116.
shows the components of the CX116.
Huawei CX116 Pass Through Module
White Paper
1 Overview
Issue 05 (2017-03-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8