Applicable Environment
The user can monitor the network by configuring an alarm threshold. After monitoring
conditions are configured, when the monitored item in the test result exceeds the configured
upper or lower threshold, the device sends alarms to the NM station. Therefore, the user can
monitor the real-time operation status of the network.
Pre-configuration Tasks
Before configuring the threshold for the NQA alarm, complete the following task:
l
Configuring a test instance
Data Preparation
To configure the threshold for the NQA alarm, you need the following data.
No.
Data
1
Number of the event corresponding to the threshold
2
Number of the alarm threshold
3
Upper threshold
4
Lower threshold
6.18.2 Configuring the Event Corresponding to the Alarm
Threshold
This part describes the actions that the system needs to perform in response to the threshold
exceeding, such as generating logs, generating traps, or generating logs and traps.
Context
Do as follows on the NQA client:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
nqa event
event-entry
{
linkage
admin-name
test-name
|
log
|
trap
|
log-trap
|
none
} [
description
]
The event number and the corresponding event are configured.
----End