background image

Change History

Changes between document issues are cumulative. Therefore

the latest document issue contains all the

Changes in previous issues.

Change in Issue 01 (2012-05-30)

Initial commercial release.

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol

Description

NOTE

CAUTION

Indicates a potentially hazardous situation, which if not avoided, could 
result in equipment damage, data loss, performance degradation, or 
unexpected results.

Provides additional information to emphasize or supplement important 
points of the main text.

2

Summary of Contents for AP6510DN-AGN

Page 1: ...AP6510DN AGN Outdoor Wireless LAN Access Point Quick Start Guide HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...roperty of their respective holders Notice The purchased products services and features are stipulated by the contract made between Huawei and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are ...

Page 3: ...mercial release Symbol Conventions The symbols that may be found in this document are defined as follows Symbol Description NOTE CAUTION Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance degradation or unexpected results Provides additional information to emphasize or supplement important points of the main text 2 ...

Page 4: ...on bolt M4X12 hexagon socket head cap screw Hoop Hammer drill Hex key Installation accessories Device Overview Packing List Unpack the equipment Ensure that all items listed in the package list are included in the shipment If any item is missing contact the supplier Ports and indicators 5G antenna port 6 7 2 4G antenna port Connected to the feeder Connected to the feeder Item Description SN Produc...

Page 5: ...sition and use the marker level and measuring tape to mark the drilling positions where expansion bolts are installed 2 Use 8 drill bit to drill 35 40 mm deep holes in the drilling positions and install expansion bolts Screw the nut into the expansion tube hammer the expansion bolt into a hole until the flat washer is flattened against the wall and remove the nuts spring washer and flat washer in ...

Page 6: ...ews on the hoop 2 Slide the AP that has the connector fastened into the wall mounting bracket The procedure for installing the AP6510DN against a horizontal pole is similar to the procedure for installing the AP6510DN against a vertical pole Installing the Security Lock To prevent unauthorized personnel from moving the AP lock the AP The preceding figure shows the security lock The carrier should ...

Page 7: ...nnector from the AP Waterproof PG connector CAUTION Connecting network cables 1 Use a shield straight through cable Cut the cable of proper length based on the distance between the AP and the PSE device peel the insulation on both ends of the network cable and crimp the wires to RJ45 connectors 2 Make a network cable onsite according to the following pin assignment Otherwise the communication qual...

Page 8: ... one layer PVC black insulation tape three layer waterproof adhesive tape and then three layer PVC black insulation tape Stretch the waterproof adhesive tape evenly and ensure that the upper layer of the tap overlaps 1 2 of the lower layer Each layer should be attached tightly Wrap the three layer waterproof adhesive tape from bottom to up from up to bottom and from bottom to up in order Connectin...

Page 9: ...xternal conductor of the coaxial cable and those of the insulation of the shielded cable should have good electric contact with the metal shell of the equipment they connect to 4 Ground cables must be separated from signal cables to reduce interference between them 5 Do not add any switch or fuse on the ground cable 6 Do not use another device for an electrical connection with the ground cable 7 A...

Page 10: ... system is working properly but the Ethernet is not connected The wireless indicator blinks more quickly as more packets are received on the 5 GHz air port The system is working properly but the Ethernet is not connected STAs at 2 4 GHz and 5 GHz are connected Blinking green The system is working properly but the Ethernet is not connected The wireless indicator blinks more quickly as more packets ...

Page 11: ...network segment 192 168 0 1 24 The IP address should not be same as the AP s default IP address 192 168 0 1 and the subnet mask is 255 255 255 0 After the configuration is complete run the ping 192 168 0 1 command on the PC to check whether the PC can be pinged If the ping operation succeeds the connection is set up successfully If the ping operation fails The connection fails to be set up Check w...

Page 12: ...the statically configured AC IP address to discover the AC and establishes a control tunnel with the AC NOTE By default AP s go online in DHCP mode Configuring the Mode for an AP to Go Online Configuring the AP to go online in DHCP mode 1 Use Telnet to log in to the AP from a PC login admin Password The default password is admin 2 Configure the AP to go online in DHCP mode cli Enterprise AP config...

Page 13: ...ethernet show sysinfo ap_ipmode pppoe ap_ipaddr ap_ipversion 4 ap_netmask ap_gateway ac_ip1 ac_ip2 ac_ip3 ac_ip4 pppoe_username wlan huawei pppoe_pwd_type simple pppoe_password wlan huawei NOTE By default the PVID of a wired side interface is 0 and no VLAN is configured on the interface 1 Use Telnet to log in to the AP from a PC login admin Password The default password is admin 2 Configure VLANs ...

Page 14: ...to connect two or more wired or wireless LANs WDS enabled AP6510DNs can switch data packets between the LANs WDS facilitates network deployment and device installation and allows flexible networking Configuring WDS Most WDS parameters are configured on the AC For details see the AC configuration guides On an AP you can enable or disable the radio indicator that indicates the signal strength of the...

Page 15: ...he hazardous substance contained in all the homogeneous materials of this part is above the limit requirement Hazardous Substances Pb Hg Cd Cr6 PBB PBDE Part Mechanical part Board circuit module Signal cable Cable connector Power adapter Auxiliary equipment O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Declaration on Hazardous Substances in Electronic Information Products QUALIFICATI...

Page 16: ... caused by improper handling in transportation and assembly 2 The defects are caused by the fact that the product is dismantled or altered by anyone that is not from a Huawei authorized service partner 3 The defects are caused by the fact that the product is used in a harsh environment that is not suitable for the operation of the product 4 The defects are caused by any force majeure including but...

Page 17: ...HUAWEI TECHNOLOGIES CO LTD Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China www huawei com Part Number 31505366 Issue 01 ...