Simply Powerful Networking

Model: UDM

Summary of Contents for UDM

Page 1: ...Simply Powerful Networking Model UDM ...

Page 2: ...niFi App Installed Web Browser Google Chrome Other browsers may have limited functionality IMPORTANT We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power TERMS OF USE All Ethernet cabling runs must use CAT5 or above It is the professional installer s responsibility to follow local country regulations including operation...

Page 3: ...RJ45 ports support 10 100 1000 Ethernet connections By default they are set to DHCP Server with the fallback IP address 192 168 1 1 24 Internet The RJ45 port supports a 10 100 1000 Ethernet connection Set to DHCP Client by default Power Connect the included AC Power Cord ...

Page 4: ...Device is initializing deinitializing Heartbeat Firmware update in process Blue Solid Device is configured and ready Slow Flashing Client connected to device via Bluetooth BLE Off White Blue Flashing Device is in recovery mode The LED will cycle through a pattern at one second intervals between off white and blue ...

Page 5: ...he UniFi Dream Machine should be running after bootup is complete Press and hold the Reset button for about 10 seconds until the LED starts flashing and then becomes solidly lit After a few seconds the LED will turn off and the UniFi Dream Machine will automatically reboot ...

Page 6: ... UTP cabling approved for indoor use WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture Hardware Installation 1 Connect the AC Power Cord to the Power port of the UniFi Dream Machine and a power outlet ...

Page 7: ...m or Wide Area Network WAN to the Internet port 3 Connect an Ethernet cable from your computer or host system to port 1 You can use Bluetooth on your smartphone to set up the UniFi Dream Machine 4 Connect additional network devices to the other ports ...

Page 8: ...niFi Dream Machine on port 1 Go to Chrome Instructions UniFi SDN App Download and install the UniFi SDN app to configure the UniFi Dream Machine Note Ensure that Bluetooth is enabled on your mobile device You will need to set up the UniFi Dream Machine with your mobile device and be within 1 5 m 5 from where it is installed ...

Page 9: ...ed the app will automatically connect to the UniFi Dream Machine and the LED will begin to flash blue If more than one controller is detected swipe through the app screens horizontally until you locate the correct UniFi Dream Machine Then follow the on screen instructions ...

Page 10: ... https 192 168 1 1 3 Follow the on screen instructions of the Setup Wizard After you run the UniFi Setup Wizard a login screen will appear for the UniFi Controller management interface Enter the Username and Password that you created in the UniFi Setup Wizard Then click Sign in You can manage your network and view network statistics using the UniFi Controller management interface For information o...

Page 11: ... Power Adapter 24V 0 6A Supported Voltage Range 100 240VAC LED System Status Operating Frequency 2 4 GHz 5 GHz Max TX Power 2 4 GHz 5 GHz 23 dBm 26 dBm Antenna Gain 2 4 GHz 5 GHz 3 dBi 4 5 dBi Wi Fi Standards 802 11 a b g n ac ac wave2 Wireless Security WEP WPA PSK WPA Enterprise WPA WPA2 TKIP AES Operating Temperature 10 to 45 C 14 to 113 F Operating Humidity 5 to 95 Noncondensing Certifications ...

Page 12: ...lectrical Safety Information 1 Compliance is required with respect to voltage frequency and current requirements indicated on the manufacturer s label Connection to a different power source than those specified may result in improper operation damage to the equipment or pose a fire hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service sh...

Page 13: ...ordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a partic ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equip ment off and on the user is encouraged to try to correct the interference by one or more of th...

Page 14: ...t les mêmes canaux RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d au moins 20 cm et...

Page 15: ...ill help prevent potential negative consequences to the environment and human health For more detailed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem...