then HG904 calculates. The weights of the balancing masses to fix on
the selected angles are shown on the right side of the 2
nd
,
3
rd
,
4
th
and 5
th
lines.
Assure that the sums of the two angles depart from the balancing mass should be less
than 180 degree.
Stop the machine, fix balancing mass on the rotor according to the result
presented by HG904. The balancing mass is removed or remained should consist with
the settings. Restart the machine. When the rotation speed becomes steady, press
【 ↓ 】
to the next item.
Step 8: Verification
Line 9 on the left: T
he note displays‖
En ter Menu Key
‖
. P ress
〖
MENU
〗
to
right.
Line 2 on the right: All the places showing values are vacant If you hope to see
some measurement, move the cursor to there, and then the value is displayed. You can
also input the value. The method of input numbers is the same as above.
Rotation
Speed
is shown in t he 2
nd
line .When the cursor is i n the 2
nd
line,the note
displays‖
En ter to Measure
‖
. Press
ENTER
, to measure the rotation speed. The
RPM value on the right side of the 3
rd
line will update continually. And
Ampli tud e&Phas e
i s shown in the 2
nd
line .When the rotation speed becomes
stable, press
ENTER
for a moment, the HG904 begins measuring vibration. The data
in the 3
rd
line (rotation speed)
,
in the 5
th
line and in the 6
th
line (the left is amplitude
while right is phase) will update continually. When the rotation speed, amplitude and
phase all become stable, press
ENTER
for a moment to finish the measurement. The
7
th
line and the 8
th
line displays how much the vibration of point I has changed. The
user could see whether the result is usable. If the result is not acceptable, repeat the
operation. The influence coefficients could be borrowed from the last measurement.
4.2.2 WITH INFLUENCE COEFFICIENTS:
Step 1: Setting Parameters