lp-181 Rev. 3.3.15

3

High heat sources (sources generating heat 100

o

F / 37

o

C or 

greater, such as stove pipes, space heaters, etc.) may damage 
plastic  components  of  the  storage  tank  as  well  as  plastic 
vent  pipe  materials.  Such  damages  ARE  NOT  covered  by 
warranty. It is recommended to keep a minimum clearance of 
8” from high heat sources. Observe heat source manufacturer 
instructions,  as  well  as  local,  state,  provincial,  and  national 
codes, laws, regulations and ordinances when installing this 
storage tank and related components near high heat sources.
Do  not  use  this  storage  tank  for  anything  other  than  its 
intended  purpose  (as  described  in  this  manual).  Doing  so 
could  result  in  property  damage  and  WILL  VOID  product 
warranty.

A. When Servicing the Water Heating System

To avoid electric shock, disconnect electrical supply before 
performing maintenance.
To  avoid  severe  burns,  allow  storage  tank  and  associated 
equipment to cool before servicing.

B. System Water

Do not use petroleum-based cleaning or sealing compounds 
in a water heating system. Gaskets and seals in the system 
may  be  damaged.  This  can  result  in  substantial  property 
damage.
Do  not  use  “homemade  cures”  or  “patent  medicines”. 
Damage to the storage tank, substantial property damage, 
and/or serious personal injury may result.

C. Freeze Protection

NOTE:

  Consider  piping  and  installation  when  determining 

tank location. Place the storage tank as close to the boiler as 
possible in a location not prone to freezing.

Failure of the storage tank due to freeze related damage IS 
NOT covered by product warranty.

UNCRATING THE STORAGE TANK

 - Any claims for damage 

or  shortage  in  shipment  must  be  filed  immediately  against 
the transportation company by the consignee.

Households with small children, disabled, or elderly persons 
may require a 120

o

F or lower temperature setting to prevent 

severe personal injury or death due to scalding.

D. Water Temperature Adjustment

If the storage tank is going to have a set temperature above 
120

o

F, you must use an ASSE 1017 rated mixing valve to avoid 

severe burns or death from scalding temperatures.

Part 2 - Prepare the Storage Tank

Remove all sides of the shipping crate to allow the tank to be 
moved into its installation location.

COLD WEATHER HANDLING

  -  If  the  storage  tank  has  been 

stored in a very cold location (BELOW 0

o

F) before installation, 

handle  with  care  until  the  components  come  to  room 
temperature.  Failure  to  do  so  could  result  in  damage  to  the 
storage tank.

A. Locating the Storage Tank

This  storage  tank  is  certified  for  indoor  use  only.  DO  NOT 
INSTALL OUTDOORS. Outdoor installations ARE NOT covered 
by warranty.
Choose  a  location  for  the  storage  tank  as  centralized  to  the 
piping  system  as  possible.  Also,  locate  the  storage  tank  and 
domestic water piping where it will not be exposed to freezing 
temperatures. All piping should be insulated. Additionally, place 
the storage tank so that the drain, controls, and inlets/outlets 
are easily accessible.

Locate the storage tank where any leakage from the relief valve, 
related piping, tank, or connections will not result in damage to 
surrounding areas or lower floors of the building. The storage 
tank should be located near a floor drain or installed in a drain 
pan. Leakage damages ARE NOT covered by warranty.

NOTE: 

To save on heating costs and improve energy efficiency 

keep  the  distance  between  the  boiler  and  storage  tank  to  a 
minimum  to  reduce  heat  loss  from  excess  piping  and  keep 
friction loss at a minimum. Ensure all piping between the boiler 
and storage tank is properly insulated to minimize heat loss.
The storage tank may be located some distance from the boiler 
provided  the  circulator  meets  flow  requirements. The  greater 
the distance from the boiler to the storage tank the longer the 
response will be to a call for hot water.
This storage tank must be installed vertical on a level surface.

NOTE:

  In  the  State  of  California,  the  water  heater  must  be 

braced,  anchored,  or  strapped  to  avoid  moving  during  an 
earthquake. Contact local utilities for code requirements in your 
area.  Visit  http://www.dsa.dgs.ca.gov  or  call  1-916-445-8100 
and request instructions.
However,  applicable  local  codes  shall  govern  installation. 
For  residential  water  heaters  of  a  capacity  of  greater  than  52 
gallons,  consult  the  local  building  jurisdiction  for  acceptable 
bracing procedures.

NOTE: 

If  you  do  not  provide  the  minimum  clearances  shown 

in Figure 1, it might not be possible to service the storage tank 
without removing it from the space. 

Ensure the location can support the entire filled weight of the 
storage tank. Failure to properly support the storage tank could 
result in property damage, severe personal injury, or death.

This storage tank must not be located near flammable liquids 
such as gasoline, butane, liquefied propane, adhesives, solvents, 
paint thinners, etc., as the controls of this storage tank could 
ignite these vapors and cause an explosion resulting in property 
damage, severe personal injury, or death.

Summary of Contents for Superstor GL-119

Page 1: ...lure to do so could result in substantial property damage severe personal injury or death HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature The surfaces of these products contacted by potable consumable water contain less than 0 25 lead by weight as required by the Safe DrinkingWater Act Section 1417 NOTETO C...

Page 2: ...des and utility company requirements Installations Must Comply With Local state provincial and national codes laws regulations and ordinances Part 1 General Safety Information This storage tank is approved for indoor installations only and is not intended for use in swimming pool applications Clearance to combustible materials 0 top bottom sides and back Tank must have room for service 24 front an...

Page 3: ...ome to room temperature Failure to do so could result in damage to the storage tank A Locating the Storage Tank This storage tank is certified for indoor use only DO NOT INSTALL OUTDOORS Outdoor installations ARE NOT covered by warranty Choose a location for the storage tank as centralized to the piping system as possible Also locate the storage tank and domestic water piping where it will not be ...

Page 4: ...7 Hard 120 180 7 10 5 Very Hard 180 and over 10 5 and over If the hardness of the water exceeds the maximum level of 7 grains per gallon the water should be softened to a hardness level no lower than 5 grains per gallon Water softened as low as 0 to 1 grain per gallon may be under saturated with respect to calcium carbonate resulting in water that is aggressive and corrosive pH of Water pH is a me...

Page 5: ...ents for relief valves for water heaters ANSI Z21 22 and CAN1 4 4 by a nationally recognized lab that maintains periodic inspection of production of listed equipment The T P valve must be plumbed down so discharge will exit at least 6 above the structural floor and not contact any live electrical parts In the bottom of the tee branch vertically down install a 3 4 NPT x 3 4 minimum tube adapter The...

Page 6: ...r time rendering the valve inoperative Such conditions can only be detected if the valve and its components are physically removed and inspected Do not attempt to conduct an inspection on your own Contact your plumbing contractor for a re inspection to assure continued safety FAILURE TO RE INSPECT THE T P VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE AND OR PRESSURE BUILD UPWHICHCAN RESULT ...

Page 7: ...torage tank open a hot water tap to release air in the tank and piping to ensure proper storage tank operation Failure to ensure the storage tank is full before turning on the system could result in damage to the water heating system and property damage Such damages ARE NOT covered by warranty 2 Check the system for leaks Fix any leaks before continuing the installation Failure to do so could resu...

Page 8: ...codes Verify system pressure is in the safe operating range Temperatures Verify safe settings on MixingValve if installed in system Electrical Smoke and CO Detectors Verify devices are installed and working properly Change batteries if nec essary Circuit Breakers Check to see that the circuit breaker is clearly labeled Exercise circuit breaker Connections Check wire connections Make sure they are ...

Page 9: ...t enough space heat Boiler sized too small Consult chart Slow recovery Circulator head capacity too low T PValve Discharges HotTubs Spas Multiple Showers High Demand Problem Possible Solution Problem Possible Solution Tank temperature too high Lower tank temperature Pressure too low Check line pressure for restriction Water expands when heated Install expansion tank Tank recovery slow Slow startup...

Page 10: ...e combination temperature and relief valve will not result in damage to the area adjacent to the storage tank or lower floors of the structure 5 Any failed components of the heat system not manufactured by HTP as part of the storage tank 6 Storage tanks repaired or altered without the prior written approval of HTP 7 Damages malfunctions or failures resulting from failure to install the storage tan...

Page 11: ...ED BY ANY FAILURE OF HTP TO MEET ANY OBLIGATION UNDER THIS AGREEMENT INCLUDING THE OBLIGATION TO REPAIR AND REPLACE SET FORTH ABOVE NO AGREEMENT VARYING OR EXTENDING THE FOREGOING WARRANTIES REMEDIES OR THIS LIMITATION WILL BE BINDING UPON HTP UNLESS IN WRITING AND SIGNED BY A DULY AUTHORIZED OFFICER OF HTP THE WARRANTIES STATED HEREIN ARE NOT TRANSFERABLE AND SHALL BE FOR THE BENEFIT OF THE ORIGI...

Page 12: ...ame Date of Installation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer IMPORTANT Customer Please only sign after the installer has fully reviewed the installation safety proper operation and maintenance of the system If the system has any problems please call the installer If you are unable to make co...

Reviews: