lp-181 Rev. 3.3.15
3
High heat sources (sources generating heat 100
o
F / 37
o
C or
greater, such as stove pipes, space heaters, etc.) may damage
plastic components of the storage tank as well as plastic
vent pipe materials. Such damages ARE NOT covered by
warranty. It is recommended to keep a minimum clearance of
8” from high heat sources. Observe heat source manufacturer
instructions, as well as local, state, provincial, and national
codes, laws, regulations and ordinances when installing this
storage tank and related components near high heat sources.
Do not use this storage tank for anything other than its
intended purpose (as described in this manual). Doing so
could result in property damage and WILL VOID product
warranty.
A. When Servicing the Water Heating System
To avoid electric shock, disconnect electrical supply before
performing maintenance.
To avoid severe burns, allow storage tank and associated
equipment to cool before servicing.
B. System Water
Do not use petroleum-based cleaning or sealing compounds
in a water heating system. Gaskets and seals in the system
may be damaged. This can result in substantial property
damage.
Do not use “homemade cures” or “patent medicines”.
Damage to the storage tank, substantial property damage,
and/or serious personal injury may result.
C. Freeze Protection
NOTE:
Consider piping and installation when determining
tank location. Place the storage tank as close to the boiler as
possible in a location not prone to freezing.
Failure of the storage tank due to freeze related damage IS
NOT covered by product warranty.
UNCRATING THE STORAGE TANK
- Any claims for damage
or shortage in shipment must be filed immediately against
the transportation company by the consignee.
Households with small children, disabled, or elderly persons
may require a 120
o
F or lower temperature setting to prevent
severe personal injury or death due to scalding.
D. Water Temperature Adjustment
If the storage tank is going to have a set temperature above
120
o
F, you must use an ASSE 1017 rated mixing valve to avoid
severe burns or death from scalding temperatures.
Part 2 - Prepare the Storage Tank
Remove all sides of the shipping crate to allow the tank to be
moved into its installation location.
COLD WEATHER HANDLING
- If the storage tank has been
stored in a very cold location (BELOW 0
o
F) before installation,
handle with care until the components come to room
temperature. Failure to do so could result in damage to the
storage tank.
A. Locating the Storage Tank
This storage tank is certified for indoor use only. DO NOT
INSTALL OUTDOORS. Outdoor installations ARE NOT covered
by warranty.
Choose a location for the storage tank as centralized to the
piping system as possible. Also, locate the storage tank and
domestic water piping where it will not be exposed to freezing
temperatures. All piping should be insulated. Additionally, place
the storage tank so that the drain, controls, and inlets/outlets
are easily accessible.
Locate the storage tank where any leakage from the relief valve,
related piping, tank, or connections will not result in damage to
surrounding areas or lower floors of the building. The storage
tank should be located near a floor drain or installed in a drain
pan. Leakage damages ARE NOT covered by warranty.
NOTE:
To save on heating costs and improve energy efficiency
keep the distance between the boiler and storage tank to a
minimum to reduce heat loss from excess piping and keep
friction loss at a minimum. Ensure all piping between the boiler
and storage tank is properly insulated to minimize heat loss.
The storage tank may be located some distance from the boiler
provided the circulator meets flow requirements. The greater
the distance from the boiler to the storage tank the longer the
response will be to a call for hot water.
This storage tank must be installed vertical on a level surface.
NOTE:
In the State of California, the water heater must be
braced, anchored, or strapped to avoid moving during an
earthquake. Contact local utilities for code requirements in your
area. Visit http://www.dsa.dgs.ca.gov or call 1-916-445-8100
and request instructions.
However, applicable local codes shall govern installation.
For residential water heaters of a capacity of greater than 52
gallons, consult the local building jurisdiction for acceptable
bracing procedures.
NOTE:
If you do not provide the minimum clearances shown
in Figure 1, it might not be possible to service the storage tank
without removing it from the space.
Ensure the location can support the entire filled weight of the
storage tank. Failure to properly support the storage tank could
result in property damage, severe personal injury, or death.
This storage tank must not be located near flammable liquids
such as gasoline, butane, liquefied propane, adhesives, solvents,
paint thinners, etc., as the controls of this storage tank could
ignite these vapors and cause an explosion resulting in property
damage, severe personal injury, or death.