420010970304 - LP-700 Rev. 000 Rel. 002 Date 4.21.21
44
Figure 46 - Two Pipe Roof Venting
Figure 47 - Unbalanced Venting - Roof Exhaust and Sidewall Intake
NOTE: These drawings are meant to demonstrate system venting only. The installer is responsible for all equipment and detailing required
by local codes.
Roof Venting Options - Direct Vent Installation
Two Pipe Termination
Unbalanced Termination (Roof Exhaust / Sidewall Intake)
Exhaust must terminate a minimum of 18” above the air intake
termination. See Figure 50 for more details.
WARNING
!
Exhaust must terminate a minimum of 12” above snow level. See
Figure 51 for more details.
WARNING
!
Concentric Termination
3” Polypro / Innoflue Concentric Termination illustrated. See Figure
52 for more details.
WARNING
!
3” IPEX Concentric Termination illustrated. See Figure 53 for more
details.
WARNING
!
Figure 48 - Roof Concentric Termination (with Optional IPEX kit)
Figure 49 - Roof Concentric Termination (with Optional Duravent /
InnoFlue Kit)