HTC confidential
© 2004, HTC Corporation. All rights reserved.
TOTAL 69 CONT.ON. 33 PAGE NO. 32
9. Power on.
10. Measure flight mode current
Wait about 1 minutes, display will be off, in
this condition, please check current value on
the current meter,
Current value must under
5 mA
,
if over, it
means M/B failed, please replace M/B for
repair.
11. Switch OFF the unit.
12. Measure power off current
Check current value on the current meter,
Current value must under
0.3 mA,
if over, it
means M/B failed, please replace M/B for
repair.