5. Audio Jack (CON601)
5.1 If the connector is broken, warp or doesn’t work properly (measure by scope), replace it.
5.2 If the connector still doesn’t work properly after replace new one, please replace the M/B.
6. LCD FPC Connector (CON702)
6.1 If the connector is broken, warp or doesn’t work properly (measure by scope), replace it.
6.2 If the connector still doesn’t work properly after replace new one, please replace the M/B.
6.3 Place solder-proof tape on CON702 to prevent it melted when using heater gun to remove CON702.
7. Switch Board FPC Connector (CON700)
7.1 If the connector is broken, warp or doesn’t work properly (measure by scope), replace it.
7.2 If the connector still doesn’t work properly after replace new one, please replace the M/B.
7.3 Place solder-proof tape on CON700 to prevent it melted when using heater gun to remove CON700
.
8. Battery Connector (CON301)
8.1 If the connector is broken, warp or doesn’t work properly (measure by scope), replace it.
8.2 If the connector still doesn’t work properly after replace new one, please replace the M/B.
9. SIM Card Connector (U505)
9.1 If the connector is broken, warp or doesn’t work properly (measure by scope), replace it.
9.2 If the connector still doesn’t work properly after replace new one, please replace the M/B.
9.3
Use solder iron only to replace new component. DO NOT use Heater Gun to remove
component to prevent next connector melted.
10. Antenna Switch (SW1)
10.1 If the switch is broken, warp or doesn’t work properly (measure by scope), replace it.
10.2 If the switch still doesn’t work properly after replace new one, please replace the M/B.
11. Battery Detector Switch (SW700)
11.1 If the switch is broken, warp or doesn’t work properly (measure by scope), replace it.
11.2 If the switch still doesn’t work properly after replace new one, please replace the M/B.
12. Volume Control Switch (SW701)
12.1 If the switch is broken, warp or doesn’t work properly (measure by scope), replace it.
12.2 If the switch still doesn’t work properly after replace new one, please replace the M/B.