HT60
EN - 18
Continuity test with buzzer
Function Buzzer
Test
current
Protection against
overcharge
<30
<0.3mA 250VDC/ACrms
Duty cycle (Autorange)
Range Resolution
Accuracy
Sensitivity
Protection against
overcharge
0.5 - 99%
0.1%
(1.2%rdg + 2dgt)
>8Vrms 250VDC/ACrms
100
s< pulse duration <100ms; Frequency range: 5Hz
150kHz
Note
: in AC Voltage range, frequency range is: 10Hz
10kHz ; Sensitivity: > 15Vrms
Frequency (electrical circuits)
Campo Risoluzione
Incertezza
Protezione contro i
sovraccarichi
10Hz
10kHz
0.001Hz ÷ 0.01kHz
(1.5%rdg + 5dgt)
600VDC/ACrms
Sensitivity: >15Vrms
Frequency (electronic circuits)
Range Resolution
Accuracy
Higher
Protection against
overcharge
5.000Hz 0.001Hz
(1.5%rdg + 5dgt)
>8Vrms 250VDC/ACrms
50.00Hz
0.01Hz
500.0Hz
0.1Hz
(1.2%rdg + 3dgt)
5.000kHz
1Hz
50.00kHz
10Hz
500.0kHz
100Hz
5.000MHz
1kHz
(1.5%rdg + 4dgt)
10.00MHz
10kHz
Note
: in AC Voltage range, frequency range is: 10Hz
10kHz ; Sensitivity: > 15Vrms
Capacitance (Autorange)
Range
Resolution
Accuracy
Protection against overcharge
40.00nF 0.01nF
(5.0%rdg + 7dgt)
250VDC/ACrms
400.0nF 0.1nF
(3.0%rdg + 5dgt)
4.000
F 0.001
F
40.00
F 0.01
F
100.0
F 0.1
F
(5.0%rdg + 5dgt)
Temperature with K probe (Autorange)
Range Resolution
Accuracy
(*)
Protection against
overcharge
-20°C ÷ 400°C
0.1°C
(3.0%r 5°C)
250VDC/ACrms
400°C ÷ 760°C
1°C
-4°F ÷ 400°F
0.1°F
(3.0%r 9°F)
400°F ÷ 1400°F
1°F
(*) Accuracy of the only instrument without probe
Summary of Contents for HT60
Page 3: ... Copyright HT ITALIA 2017 Versione IT 1 02 07 04 2017 ITALIANO Manuale d uso ...
Page 24: ......
Page 25: ... Copyright HT ITALIA 2017 Version EN 1 02 07 04 2017 ENGLISH User manual ...
Page 46: ......
Page 47: ... Copyright HT ITALIA 2017 Versión ES 1 02 07 04 2017 ESPAÑOL Manual de instrucciones ...
Page 68: ......
Page 69: ... Copyright HT ITALIA 2017 Version DE 1 02 07 04 2017 DEUTSCH Bedienungsanleitung ...
Page 90: ......
Page 91: ... Copyright HT ITALIA 2017 Version FR 1 02 07 04 2017 FRANÇAIS Manuel d utilisation ...