HT60
EN - 4
2. GENERAL DESCRIPTION
HT60 carries out the following measurements in Autorange:
DC
voltage
AC
TRMS
voltage
DC/AC voltage with low impedance (LoZ)
Resistance and Continuity test
Capacity
Frequency
Duty
Cycle
Diode
test
Temperature with K-type probe
Each of these functions can be selected using the 7-position rotary switch, including an
OFF position. The instrument is also provided with a
HOLD
function key to enable
freezing the measured value on the display and to activate the display
’
s backlight, an
Hz%
key to select frequency and duty cycle tests, a
REL
key to carry out relative measurements
and a
MODE
key to select resistance measurement, continuity test, diode test and
capacity test. The selected quantity appears on the LCD display with the indication of the
measuring unit and of the enabled functions. The instrument is also equipped with an Auto
Power OFF device which automatically switches it off approx. 30 minutes after the last
time the instrument was used.
2.1. MEASURING
AVERAGE
VALUES ANDTRMS VALUES
Measuring instruments of alternating quantities are divided into two big families:
AVERAGE-VALUE meters: instruments measuring the value of the sole wave at
fundamental frequency (50 or 60 Hz).
TRMS (True Root Mean Square) VALUE meters: instruments measuring the TRMS
value of the quantity being tested.
With a perfectly sinusoidal wave, the two families of instruments provide identical results.
With distorted waves, instead, the readings shall differ. Average-value meters provide the
RMS value of the sole fundamental wave; TRSM meters, instead, provide the RMS value
of the whole wave, including harmonics (within the instruments bandwidth). Therefore, by
measuring the same quantity with instruments from both families, the values obtained are
identical only if the wave is perfectly sinusoidal. In case it is distorted, TRMS meters shall
provide higher values than the values read by average-value meters.
2.2. DEFINITION OF TRUE ROOT MEAN SQUARE VALUE AND CREST FACTOR
The root mean square value of current is defined as follows:
“
In a time equal to a period,
an alternating current with a root mean square value of 1A intensity, circulating on a
resistor, dissipates the same energy that, during the same time, would be dissipated by a
direct current with an intensity of 1A
". This definition results in the numeric expression:
G=
T
t
t
dt
t
g
T
0
0
)
(
1
2
The root mean square value is indicated with the acronym RMS
.
The Crest Factor is defined as the relationship between the Peak Value of a signal and its
RMS value: CF (G)=
RMS
p
G
G
This value changes with the signal waveform, for a purely
sinusoidal wave it is
2
=1.41. In case of distortion, the Crest Factor takes higher values
as wave distortion increases.
Summary of Contents for HT60
Page 3: ... Copyright HT ITALIA 2017 Versione IT 1 02 07 04 2017 ITALIANO Manuale d uso ...
Page 24: ......
Page 25: ... Copyright HT ITALIA 2017 Version EN 1 02 07 04 2017 ENGLISH User manual ...
Page 46: ......
Page 47: ... Copyright HT ITALIA 2017 Versión ES 1 02 07 04 2017 ESPAÑOL Manual de instrucciones ...
Page 68: ......
Page 69: ... Copyright HT ITALIA 2017 Version DE 1 02 07 04 2017 DEUTSCH Bedienungsanleitung ...
Page 90: ......
Page 91: ... Copyright HT ITALIA 2017 Version FR 1 02 07 04 2017 FRANÇAIS Manuel d utilisation ...