background image

USER MANUAL 

 

Professional voltage detector HT20 

 

4. Description

 

 

 

 

 

5. Operating instruction 

Consider the herewith steps for a correct use of HT20: 

Voltage detection sensor 

Reference mark for CAT IV measurements 

Hand safety protection 

4 ON/OFF 

key 

5 Pen 

clip 

White LED torch 

Fit part for battery cover sleigh 

Battery cover sleigh 

1. Safety precautions and procedures 

Please follow the herewith indications before and during 
the performance of any test with the instrument: 

 

 

CAUTION 

 

 

An improper use can damage the 
instrument and/or its components or 
injure the operator 

 

Avoid using the instrument in rooms 
where explosive gas, combustible gas, 
steam or excessive dust are present 

 

Do not perform any test if you notice 
anomalous conditions such as 
breakages, deformations, fractures, 
leakages of battery liquid on meter 

 

Do not perform any test exceeding the 
declared voltage conditions 

 

Do not perform measurements under 
environmental conditions  exceeding 
the declared limits 

 

Do not perform any voltage detection 
with operator’s hand beyond the hand 
safety protection 

 

2. Introduction 

HT20 meter can perform AC voltage detection with visible 
LED red and acoustic buzzer indications. A white LED is 
can be also activated by pressing ON/OFF key. 
 

3. Features 

  AC voltage detection with and without contact 

  AC voltage detection on conductive and insulated parts

  Test on outlets, cables and/or electrical appliances 

  Visible red LED and acoustic buzzer indications 

  White torch LED with ON/OFF key 

  Practical pen clip and very small size 

 Auto 

Power 

OFF 

  Meter suitable for any electrical installer 

1.  Perform a initial test with meter on a energized circuit. 

Replace internal batteries if the red LED do not turn on 
and/or the buzzer do not sound 

2.  Position the sensor close to or in contact with the point 

under test then verify that the red LED is on and buzzer 
sounds continuously as evidence of voltage detection. 
Do not perform test with the operator’s hand 
beyond the hand safety protection and position not 
insulated wires beyond the CAT IV reference mark 
(see part 2 of picture)
 

3.  If necessary press ON/OFF key to turn on the white 

LED torch 

 

6. Batteries replacement 

Follow the herewith steps to replace internal batteries: 
1.  Remove the meter from any voltage source 
2.  Perform a small pressure on battery cover sleigh (see 

part 8 of picture) 

3.  Shift the battery cover sleigh from the meter 
4.  Replace the batteries with new ones of the same type 

and pay attention to keep to correct polarity indication 

5.  Fit the battery cover sleigh to the meter  
6.  Used batteries must not be disposed of as urban waste

 

CAUTION: this symbol indicates that the 
equipment and its accessories shall be subject 
to a separate collection and correct disposal 

 

7. Technical specifications 

 

Voltage reference range: 100 

 1000V AC to ground 

 

Frequency reference range: 50/60Hz 

 

Meter indications: visible LED and acoustic buzzer 

 

Safety: IEC/EN61010-1 

 

Category of measurement: CAT IV 1000V 

 

Pollution degree: 2 

 

Batteries: 2 x 1.5V alkaline type AAA IEC LR03 

 

Working temperature: -10°C 

 50°C (14°F 

 122°F) 

 

Working humidity: -10

40°C;<75%HR;  

40 

 50°C <45%HR 

 

Dimensions: 160(L)x26(W)x20(H)mm;6(L)x1(W)x1(H)” 

Weight (included batteries): 48g (0.1lb) 

Release EN 3.01 – 17/09/2012 

 

Summary of Contents for HT20

Page 1: ...y indicador acústico Linterna luminosa para un uso práctico De reducidas dimensiones con soporte clip Instrumento para cada instalador eléctrico 1 Probar el HT20 en un circuito con tensión presente Substituir las pilas si el LED rojo no encender y o el indicator acustico no trabajan 2 Posicionar el sensor en proximidad o en contacto del punto de prueba y verificar l encenderse de LED rojo y del in...

Page 2: ...lip and very small size Auto Power OFF Meter suitable for any electrical installer 1 Perform a initial test with meter on a energized circuit Replace internal batteries if the red LED do not turn on and or the buzzer do not sound 2 Position the sensor close to or in contact with the point under test then verify that the red LED is on and buzzer sounds continuously as evidence of voltage detection ...

Page 3: ...Prüflings ON OFF Taste Optische Anzeige rote LED und akustischer Summer zur Spannungsanzeige Sehr kompakte Ausführung mit praktischem Taschenclip 1 Um das ordnungsgemäße Arbeiten des HT20 sicherzustellen ist der HT20 vor dem Gebrauch an einem spannungsführenden Kreis zu prüfen Ersetzen Sie die Batterien sofern die rote LED nicht aufleuchtet oder der Summer nicht ertönt 2 Positionieren Sie den Sens...

Page 4: ... ou circuits électriques Indication de tension par LED rouge et buzzer Torche blanche activée en appuyant sur ON OFF Dimensions réduites avec fermoir de poche Instrument idéal pour tout installateur électrique 1 Effectuer un test initial avec l instrument sur un circuit sous tension Remplacer les batteries si le témoin LED rouge ne s allume pas ou et si le buzzer ne sonne pas 2 Positionner le capt...

Page 5: ...nsão com indicador sonoro Lanterna com luz branca com botão ON OFF Dimensões reduzidas com suporte de bolso tipo clip Instrumento ideal para qualquer instalador eléctrico 1 Testar preliminarmente o instrumento num circuito sob tensão Substituir as pilhas internas se o LED vermelho indicador não se acende e ou o indicador sonoro não emite sons 2 Colocar o sensor na proximidade ou em contacto com o ...

Reviews: