HT38
EN - 6
6 OPERATING
INSTRUCTIONS
6.1 LOCALIZATION OF PROTECTION DEVICES WITHIN A CONTROL PANEL
1. Switch on the received by pressing the
/Reset button and check that the red LED
(see
Fig. 1
– part 2) is on and that the unit sounds intermittently (
) at regular intervals.
Should it not, check and, if necessary, replace the internal battery (see § 7.1) or
contact HT’s After-sales Service.
2. Connect the transmitter to the electric mains through the integrated Schuko plug. The
ON LED on the front of the instrument (see Fig. 2 – part 2) turns on and the unit
automatically activates and sends the signal into the circuit to be tested (see Fig. 3).
Fig. 3: Connection of transmitter to the circuit to be tested
3. Bring the sensitive element of the receiver above the transmitter (see Fig. 3) and check
for a continuous sound (
). The green LED turning on (see
Fig. 1
– part 3) and the red
LED turning off (see
Fig. 1
– part 2) indicate that the signal has been recognized.
4. Keep the receiver near the energized control panels and move in the direction in which
the intermittent sound of the unit becomes faster to signal that the source to be
searched is near (see Fig. 3).
Summary of Contents for 8033100185218
Page 2: ......
Page 4: ......
Page 5: ... Copyright HT ITALIA 2016 Versione IT 1 00 08 01 2016 ITALIANO Manuale d uso ...
Page 16: ......
Page 17: ... Copyright HT ITALIA 2016 Release EN 1 00 08 01 2016 ENGLISH User manual ...
Page 28: ......
Page 29: ... Copyright HT ITALIA 2016 Versión ES 1 00 08 01 2016 ESPAÑOL Manual de instrucciones ...
Page 40: ......
Page 41: ... Copyright HT ITALIA 2016 Ausführung DE 1 00 08 01 2016 DEUTSCH Bedienungsanleitung ...
Page 52: ......
Page 53: ... Copyright HT ITALIA 2016 Version FR 1 00 08 01 2016 FRANÇAIS Manuel d utilisation ...