– Run the press ram forwards and backwards several times and, whilst the press ram is
as far forward as possible, recheck the oil level
– Fill more oil if required
– Screw on a new venting fi lter
– Mount the cover (H) onto the unit again
Note
Observe the applicable accident prevention regulations when handling
cleaning agents and solvents.
Observe the environment protection regulations when disposing of waste
oil.
Never mix hydraulic fl uid and cleaning agent mixtures with waste oil.
Collect these substances in separate containers and dispose of them
according to the regulations.
ÖL
OIL
HUILE
OLIO
ACEITE
ÓLEO
OLIE
OLJA
ÖLJY
5.2.2
Lubricating the movable parts
The press ram guide (black plastic blocks) is maintenance free.
Do not lubricate the tracks in the press chamber!
–
Should any grinding or humming noises arise, place a drop of biodegradable
lubricating oil on the exposed tracks of the press chamber fl oor.
–
Replace the plastic blocks of the press ram guide every 2 years.
–
Consult HSM customer service in this regard.
– Lubricate all movable parts and hinges as required, especially the door hinges and the bear-