5 .Place the muzzle of tool perpendicular to work suface without tilting the tool.Push tool
against work surface until sliding action of barrel stops.
6. Grasp muzzle cap and slide barrel forward rapidly until it stops. Push
barrel assembly back into tool to the closed position . This advances the
power load strip and resets the piston for the next fastening.
WARNING: Do not depress barrel assembly past the closed position when
loading new power fastener. Live power load is in firing position.
7.Should the tool fail to fire, hold the muzzle firmly against the work surface for
30 seconds. Release the trigger and remove pressure on the tool while holding
the muzzle against the work surface. Again press the tool firmly against the
work surface and pull the trigger. If the tool still fails to fire, hold the tool
firmly against the work surface for another
30
seconds before advancing the
power load strip. Use remaining loads in strip. Discard power load strip into
water or oil.