8
General Plumbing Requirements
The appliance must be installed in accordance with, and comply to, the current: IEE Regulations, Building Regulations,
Building Standards (Scotland) (Consolidation), Building Regulations (Northern Ireland), local water by-laws, Health &
Safety Document 635 (The Electricity at Work Regulations 1989) and any other local requirements.
British and Irish standards
Where no specific instruction is given, reference should be made to the relevant British and/or Irish Standard codes of
Practice.
BS7074:1 Code of practice for domestic and hot water supply
BS7593 Treatment of water in domestic hot water central heating systems
ECTI
National rules for electrical installations
Keep following conditions in mind during installation:
• The unit must be stored and installed in a frost free area.
• The unit must not be exposed to direct sunlight.
• Ambient temperature must be b50C and +400
C.
• Humidity must be between 20% and 80%.
• Temperatures of components in the unit and connected to the unit can reach high temperatures. Contact may
lead to burns.
Fitting and modifications
Fitting the appliance and any controls to the appliance may only be carried out by a competent engineer. Any misuse
or unauthorised modifications to the appliance or associated components and systems could invalidate the guarantee
and may lead to serious injury or even death. The manufacturer accepts no liability arising from any such actions,
excluding statutory rights.
District heating
CAUTION!
Components, pipes in, and connected to, the unit may be hot. The EcoAdvance Instant is designed for usage with
district heating systems up to 900C. The pipes and components in the set can reach these temperatures. Contact may
lead to burns.
Keep following conditions in mind during installation:
• Maximum pressure supplied by the district heating network is 10 bar.
• Maximum supplied temperature by the distict heating network is 900
C.
• Minimal supply temperature is setpoint DHW + 50
C.
Domestic water
Keep following condition in mind during installation:
• Maximum pressure supplied by the domestic water circuit is 10 bar.
• All seals, joints and compounds (including flux and solder) and components used as part of the secondary
domestic water system must be approved.