6 Operation and regulation
86
HSD S.p.A. © - 0106h03a.fm100713
6.9.4
Technical characteristics of the Bauer sine
encoder
Trend of signal A over time:
CHARACTERISTICS
VALUE
Rated power supply "U"
5V DC +/- 5%
Operating temperature
-30° C ÷ 85° C (-22° F ÷ 185° F)
Max. operating altitude
2000m (6500ft)
Signal input
128 pulses per ro zero notch
100 pulses per ro zero notch
A/B signal output
500 mV peak-to-peak with average value “U ref.”=U/2
1V peak-to-peak as difference of signals with
average value “U ref.” (see figures below)
A/B signal phase displacement
90° (a quarter period)
Z signal output
500 mV peak compared with idle value
U ref. ±80mV
1V peak as difference of signals with idle value U ref.-
160mV= 2.34V (see figures below)
A voltage level higher than the one specified (5V ±5%) may damage the encoder
reader.
A+
A–
A+
DIFF
= (A+) – (A–)
360° electrical de-