HIFシリーズ 
リボンケーブル結線作業方法説明書 

 

HIF SERIES

 

RIBBON CABLE CONNECTION INSTRUCTION MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

安全に使用していただくために使用前に、必ずこの取扱説明書をお読みください。

 

また、いつでもすぐに読めるように、この取扱説明書を保管してください。

 

 

CAUTION : 

Be sure to read this Instruction Manual carefully before using it to secure safety in operation.   
In addition, save this Instruction Manual so that it is available whenever necessary for review.

 

注意

 

ヒロセ電機株式会社

 

HIROSE ELECTRIC CO., LTD.

 

Aug.1.2019 Copyright 2019 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Summary of Contents for 176-7317

Page 1: ...to read this Instruction Manual carefully before using it to secure safety in operation In addition save this Instruction Manual so that it is available whenever necessary for review HIROSE ELECTRIC C...

Page 2: ...ction Tool This Manual describes the procedure for connecting ribbon cables to the HIF connectors and the details of the tool Be sure to read this Instruction Manual carefully before using it to secur...

Page 3: ...I 1 1 1 2 1 2 3 4 i Aug 1 2019 Copyright 2019 HIROSE ELECTRIC CO LTD All Rights Reserved...

Page 4: ...n 1 Such safety devices as the safety cover and the like are not attached to this tool When performing connection use this tool while fully considering so that the fingers or the like are not caught i...

Page 5: ...able jig and for adjusting the ratchet 4 Cutting allowance of cables and cautions to be taken when cutting them 5 Procedure for connecting the HIF2 IC type and DIP type 6 Procedure for connecting the...

Page 6: ...HIF2C 60PB 550 0156 7 HIF3 GPA2 HIF3 A B BA BB J N 550 0133 1 HIF1 A 01 I C H I I B 2 F H I F 2 I H I F 2 C I 6 10 14 16 20 26 30 34 40 50 60 64 HIF3 HIF3A HIF3B HIF3BA HIF3BB HIF3J HIF3N HIF3 6PD 2 5...

Page 7: ...e pressure block is included HIF3 16PD 2 54R 550 0072 9 HIF3 GPD16 exclusive pressure block is included HIF3 20PD 2 54R 550 0073 1 HIF3 GPD20 exclusive pressure block is included HIF3 26PD 2 54R 550 0...

Page 8: ...mber of poles of your connector should be prepared referring to the Listing of the HIF Series connection jigs and applicable jigs in Table 1 A pressure block and guide plate specified according to the...

Page 9: ...ed product name is in white of the pressure block C should be faced toward you 3 1 Fig 3 1 Recessed part A of pressure block holder Pressure block holder Projected part B of pressure block Pressure bl...

Page 10: ...head bolts supplied accessories diagonally as a c and b d and secure them with the M5 hexagonal wrench key See Fig 3 4 For the HIF2 lower the press handle so that the guide pins of the pressure block...

Page 11: ...From this state securely tighten the bolt while checking how the ratchet is released During the adjustment also check the following carefully 1 1 When you want to return the handle to its home positi...

Page 12: ...nsion of allowance to dimension L in completed connection drawing example Without clamp With clamp HIF2 IC type HIF2 14 12 5mm HIF2 14 12 5mm allowance HIF2 16 12 5mm HIF2 16 12 5mm allowance HIF2 24...

Page 13: ...jects from the cutting plane 5 HIF2 I C cedure for connecting the HIF2 IC type and DIP type Pro 1 IC 5 1 1 Place a protector on the guide plate For the IC type the protector may be oriented in either...

Page 14: ...s IC IC type connector DIP type connector A type B B type Stopper Stopper Stopper Stopper A type 5 2 Fig 5 2 B B type 3 3 Depress the handle until the ratchet locks in place After completion of connec...

Page 15: ...HIF2 IC type DIP type with a clamp is not used Correct the corrugation of cable fits in the corrugation groove of the protector Wrong the corrugation of cable does not fit in the corrugation groove o...

Page 16: ...ector may be oriented in either direction Protector Stopper Protector common to all number of poles Guides 6 1 Fig 6 1 2 6 2 2 Place the cable properly See Fig 6 2 Wrong 6 2 Fig 6 2 Not flush Not stra...

Page 17: ...ype classification Determine a desired connection type according to the direction of the mark on the cable and the filled triangle mark on the connector mark Stopper Stopper 6 3 Fig 6 3 A type B type...

Page 18: ...unit as an accessory Pressure block Depress the handle Stopper Push the take out lever 6 4 Fig 6 4 5 6 5 6 6 HRS 5 Fold the cable which has been connected Fig 6 5 as shown in Fig 6 6 press the top end...

Page 19: ...ndling the product after the completion of connection Ca 1 2 HIF2 HIF3 3 HIF2 4 1 Do not re use the connector and cable which have been used once since the re use can cause a malfunction 2 Be sure to...

Page 20: ...4R S A F2 HIF2 D 2 54R S type HIF2 D 2 54R S type HIF2B D 2 54R S A type the example diagram indicates the F2 type HIF2B D 2 54R S A type the example diagram indicates the F2 type AA AA type AA AA typ...

Page 21: ...S B HIF2B D 2 54R S B type HIF2B D 2 54R S B HIF2B D 2 54R S B type AA AA type AA AA type AA AA type AA AA type Cable mark Dip type Dip IC IC type AB AB type AB AB type AB AB type AB AB type Cable ma...

Page 22: ...circuit diagram for HIF3 AB AB type Cable mark A AB type AD AD type AD AD type CD CD type CD CD type AD AD type CD CD type Cable mark D Cable make D C Aug 1 2019 Copyright 2019 HIROSE ELECTRIC CO LTD...

Page 23: ...AC AC type CC CC type AA AA type AC AC type Cable mark Cable mark Cable mark C A AA CC CC type AA type Aug 1 2019 Copyright 2019 HIROSE ELECTRIC CO LTD All Rights Reserved...

Page 24: ...tact our Marketing Department 4 It should be understood that notwithstanding the aforementioned item 3 we assume no liability to any claim for loss or failure to earn profit resulting from the use of...

Page 25: ...6235 Phone Tele Fax 805 5227958 805 5223217 Hirose Electric GmbH Zeppelinstraze 42 73760 Ostfildern Kemnat Phone Tele Fax 0711 4560021 0711 4560729 Hirose Electric UK Ltd Crownhill Business Centre 22...

Reviews: