VDPL300QF
HQPOWER™
5
6 Built-in
programs
0 10
No
function
11 36
Program
1
37 62
Program
2
63 88
Program
3
89 114
Program
4
115 130
Program
5
131 156
Program
6
157 182
Program
7
183 208
Program
8
209
250
Random all programs
251
255
Sound to light mode
DMX512 Connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side
to the male 3-pin XLR input of the
VDPL300QF
. Multiple
VDPL300QF
s can be linked through serial
linking. The linking cable should be a two-core screened cable with XLR input and output connectors.
DMX512 Chain with Termination
A DMX terminator is recommended for installations where the DMX cable has
to run a long distance or is in an electrically noisy environment (e.g. discos).
The terminator prevents corruption of the digital control signal by electrical
noise. The DMX terminator is simply an XLR plug with a 120
Ω
resistor
between pins 2 and 3, which is then plugged into the XLR output socket of
the last device in the chain.
Please see illustration.
DMX Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This start address is the channel number from which the device starts to “listen” to the DMX
controller. Enter the correct number and read it from the display located on the base of the
VDPL300QF
.
You can use the same starting address for a whole group of devices or enter an individual one for
every device.
When all devices have the same address, all the
VDPL300QF
s will “listen” to the control signal on
one particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set different addresses, each device will “listen” to a separate channel
number. Changing the settings of one channel will only affect the device in question.
In the case of the 6-channel
VDPL300QF
, you will have to set the start address of the first
VDPL300QF
to 1, the second
VDPL300QF