background image

 

VDL500SM

 Rev. 

01 

 

23.12.2010

 

©Velleman nv

 

 

Familiarise yourself with the functions of the device before actually using it. Do not allow operation by 

unqualified people. Any damage that may occur will most probably be due to unprofessional use of the 

device. 

 

Use the original packaging if the device is to be transported. 

 

All modifications of the device are forbidden for safety reasons. 

 

Only use the device for its intended purpose. Other uses may lead to short circuits, burns, 

electroshocks etc. Using the device in an unauthorised way will void the warranty. 

4. Description 

Refer to the illustrations on page 2. 

power ON/OFF switch 

 

hot nozzle 

fuse  

adjustable handle 

indicator light 

 

feeder tube 

smoke generation switch 

 

liquid tank with cap 

5. Installation 

a) Smoke Liquid

 

 

Unplug the device before filling the tank. 

 

Please use non-inflammable water-based smoke fluid without oil or grease, such as 

VDLSL1

 (1 litre), 

VDLSL5

 (5 litres), or 

VDLSL5H

 (5 litres high density smoke liquid). 

 

Non-recommended smoke liquid may damage the machine and void the warranty. 

1. Unplug the device from the mains. 

2. Unscrew the cap from the tank. 

 

3. Carefully pour smoke liquid into the tank (do not overfill it!!). 

4. Screw the cap closed. 

Remark: Do not operate the device when the tank is open. 
b) Fuse

 

 

Only fit or replace a fuse when the device is unplugged from the mains. 

 

Replace a blown fuse with a fuse of the same type and rating (see “

8. Technical Specifications

”): 

1. Unplug the device from the mains. 

2. Unscrew the fuse holder at the back with an appropriate screwdriver. 

3. Remove the old fuse and install a new one. 

4. Replace the fuse holder and fasten it with the screwdriver. 

c)  Mounting the Device

 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable 

norms. 

 

The construction to which the device is attached should be able to support 10 times the weight of the 

device for one hour without deformation. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable (e.g. 

VDLSC7

 or 

VDLSC8

). 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified 

technician check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the 

installation material to be used… Have the material and the device itself checked regularly. Do not 

attempt to install the device yourself if you lack these qualifications as improper installation may result 

in injuries. 

 

Make sure there is no flammable material within a 50cm radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. Don’t connect it to a dimming pack. 

 

The installation has to be approved by an expert before the device is taken into service. 

6. Use

 

Connect the device to the mains and flick the power switch at the back of the device to ON. After the 

warm-up time (approx. 5-8 minutes) the device is ready for use. The green indicator light is now lit: 

 

Activate/deactivate the smoke output with the push button. 

 

 

Summary of Contents for VDL500SM

Page 1: ...OO MAC M Q NEB USER M GEBRU NOTICE MANUA BEDIEN L500S OKE MAC OKMACH CHINE QUINA D ELMASC MANUAL IKERSHAND E D EMPLOI AL DEL USUA NUNGSANLE SM CHINE INE FUM E DE HUMO CHINE DLEIDING ARIO ITUNG O 1 1 3...

Page 2: ...VDL500SM Rev 01 23 12 2010 Velleman nv 2...

Page 3: ...lised com l recycling servi e disposal aut t is a time contr manual thorough n transit If the d stallation touch ng operation as rain and moistu e opening the ho ain guidelines in ity for any ensu and...

Page 4: ...the back with an appropriate screwdriver 3 Remove the old fuse and install a new one 4 Replace the fuse holder and fasten it with the screwdriver c Mounting the Device Have the device installed by a...

Page 5: ...ning liquid available from your dealer Fill the tank with the cleaning liquid and let the machine run for a while When the device is cleaned remove the remaining cleaning liquid and rinse the tank tho...

Page 6: ...moet dit toe pecteer de plaat laatselijke aut M is een rookmac Lees deze hand d tijdens het tran llatie raak geen nneer het in geb egen en vochtig stel niet aanges oor het negeren d afwijzen voor est...

Page 7: ...iet te veel vloeistof in 4 Schroef de dop terug op het reservoir Opmerking Stel het toestel niet in werking wanneer het reservoir open is b Zekering U mag een zekering enkel plaatsen of vervangen wann...

Page 8: ...5 Installatie 7 Bestel eventuele reserveonderdelen bij uw plaatselijke verdeler 8 Reinig het verwarmingselement iedere 30 werkuren met een speciale reinigingsvloeistof verkrijgbaar bij uw verdeler Vul...

Page 9: ...it otre VDL500SM Lisez attentivem sultez votre reve tion toucher u squ il est en serv pluie et l humidi tation avant d o mmages surven esponsabilit po de l installation osition des va l appareil ait a...

Page 10: ...eau lectrique avant de remplacer un fusible Remplacez un fusible saut par un exemplaire identique voir 8 Sp cifications techniques 1 D branchez l appareil du r seau lectrique 2 D vissez le porte fusib...

Page 11: ...0 heures d utilisation avec un liquide de nettoyage sp ciale en vente chez votre distributeur local Remplissez le r servoir avec le liquide de nettoyage et faites marcher l appareil pendant un certain...

Page 12: ...M Es una m a cuidadosamen da o en el tran se en contacto c dad n puede sufrir e su operaci n uvia o humedad entaci n de la re instrucciones de e de ning n da ben ser realizad xpuesto a grand iente pro...

Page 13: ...aciones 1 Desatornille la tapa del portafusibles en el panel trasero con un destornillador adecuado 2 Quite el fusible fundido y reempl celo 3 Vuelva la tapa en su lugar y atorn llela c Instalaci n de...

Page 14: ...a especial que se puede comprar en la tienda de su distribuidor local Rellene el dep sito con el l quido de limpieza y haga funcionar el aparato durante un cierto tiempo Si el aparato est limpio saque...

Page 15: ...ler e rtlichen Umw sich f r Entso L500SM Diese len Nebelfluid L pr fen Sie zuers und setzen Sie s nstallation Fas ktrischen Schlag als w hrend de Feuchtigkeit und ffnen vom Netz ng der Bedienu erende...

Page 16: ...Liter Nebelfluid mit hoher Dichte Bei Verwendung nicht empfohlener Nebelfl ssigkeit k nnte das Ger t besch digt werden und erlischt den Garantieanspruch 1 Trennen Sie das Ger t von der Netzspannung 2...

Page 17: ...nnen Sie das Ger t vom Netz ehe Sie mit den Servicearbeiten anfangen 5 Verwenden Sie zur Reinigung ein feuchtes fusselfreies Tuch Verwenden Sie auf keinen Fall Alkohol oder irgendwelche L sungsmittel...

Page 18: ...toestel bv door oxidatie schokken val stof vuil vocht en door het toestel alsook zijn inhoud bv verlies van data vergoeding voor eventuele winstderving verbruiksgoederen onderdelen of hulpstukken die...

Page 19: ...manual del usuario y controle los cables las pilas etc antes de devolver el aparato Si no se encuentra un defecto en el art culo los gastos podr an correr a cargo del cliente Los gastos de transporte...

Reviews: