4. Installation 

 

a) Lamp 

 

• 

Only fit or replace a lamp when the device is unplugged from the mains.  

• 

Let a lamp cool down before replacing it as the temperature of a lamp can reach 700°C during operation. 

• 

When handling a halogen lamp, do not touch it with your bare hands. Use a cloth to insert or remove it. 

• 

Do not install lamps with a higher wattage. They get hotter than this device was designed for. 

• 

Replace any deformed or damaged lamp with a lamp of the same type (see “

7. Technical Specifications

”, p.3): 

 

1.  Unscrew the screw that holds in place the ‘lamp replacement access lid’ and gently remove the lid. 

2.  Remove the old lamp and insert the new one. 
3.  Carefully put the lid back and fix the screw. 

 

Remark: Do not operate the device when the cover is off. 

 

b) Fuse

 

 

• 

Only fit or replace a fuse when the device is unplugged from the mains. 

• 

If the lamp burns out, chances are you will need to replace the fuse as well. 

• 

Replace a blown fuse with a fuse of the same type and rating (see “

7. Technical Specifications

” on p.3): 

1.  Unscrew the fuse holder on the rear panel with an appropriate screwdriver. 
2.  Remove the old fuse and install a new one. 
3.  Replace the fuse holder and fasten it with the screwdriver. 

 

c) Mounting the Device 

 

• 

Have the unit installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms. 

• 

The construction to which the device is attached should be able to support 10 times the weight of the device for 
one hour without deformation. 

• 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

• 

Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician 
check the device once a year and once before you bring it into service. 

• 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

• 

Overhead mounting requires extensive experience: calculating work load limits, determining the installation 
material to be used… Have the material and the device itself checked regularly. Do not attempt to install the 

device yourself if you lack these qualifications as improper installation may result in injuries. 

• 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

• 

Make sure there is no flammable material within a 50cm radius of the device. 

• 

Have a qualified electrician carry out the electric connection. 

• 

Connect the device to the mains with the power plug. Don’t connect it to a dimming pack. 

• 

The installation has to be approved by an expert before the device is taken into service. 

 

Summary of Contents for SPACE FLOWER 100

Page 1: ...ice from the mains to clean it or when it is not in use Handle the power cord by the plug only There may be some smoke or a particular smell when the device is activated for the first time This is nor...

Page 2: ...th the screwdriver c Mounting the Device Have the unit installed by a qualified person respecting EN 60598 2 17 and all other applicable norms The construction to which the device is attached should b...

Page 3: ...and the fuse see 4 Installation on p 2 8 Contact your dealer for spare parts if necessary 7 Technical Specifications Power Supply max 230VAC 50Hz Power Consumption max 100W Fuse F 3A 250VAC 5 x 20mm o...

Page 4: ...stel enkel binnenshuis gebruiken met een wisselspanning van maximum 230Vac 50Hz Lichteffecten zijn niet ontworpen voor continue werking regelmatige onderbrekingen doen ze langer meegaan Schud het toes...

Page 5: ...ng is vereist voor de plaatsing van dit toestel U moet de maximumbelasting van de draagconstructie kunnen berekenen weten welk constructiemateriaal u kunt gebruiken en u moet het gebruikte materiaal e...

Page 6: ...ocs mortels Ne touchez pas l appareil lorsqu il est en usage le bo tier chauffe Prot gez l appareil contre la pluie et l humidit D branchez le c ble d alimentation avant d ouvrir le bo tier La garanti...

Page 7: ...rtez l appareil dans son emballage originel Toute modification de l appareil est interdite pour des raisons de s curit N utilisez votre VDL100CM qu sa fonction pr vue Tout autre usage peut causer des...

Page 8: ...lectrique Branchez l appareil sur le r seau lectrique par la fiche d alimentation Ne le branchez pas sur un bloc de puissance Un expert doit approuver l installation avant qu elle puisse tre prise en...

Page 9: ...rica debe llevarse a cabo por un t cnico calificado Aseg rese de que la tensi n de red no sea mayor que la tensi n indicada en las especificaciones No aplaste el cable de alimentaci n y prot jalo cont...

Page 10: ...a parte posterior del aparato y abra la tapa 2 Quite la l mpara vieja e introduzca la nueva 3 Vuelva a colocar la tapa y atornille los tornillos Observaci n No use este aparato con la caja abierta b F...

Page 11: ...n el panel posterior funcionar al ritmo de la m sica rotaci n cont nua est tico 6 Limpieza y mantenimiento 1 Apriete bien las tuercas y los tornillos y verifique que no corren 2 No modifique la caja l...

Page 12: ...ntspricht der Schutzklasse I Gem den Vorschriften muss das Ger t geerdet sein Der elektrische Anschluss darf nur von einer Fachkraft durchgef hrt werden Vergewissern Sie sich dass die anzuschlie ende...

Page 13: ...ampe nur bei uneingeschaltetem Ger t ein und wechseln Sie jede besch digte Lampe Die Lampen k nnen eine Temperatur von bis zu 700 C erreichen Lassen Sie die Lampen deshalb erst abk hlen Ber hren Sie d...

Page 14: ...ngswinkel ber den Montageb gel ein und ziehen Sie die Schrauben gut fest Entfernen Sie alle entflammbaren Materialen in einem Abstand von 50cm Der elektrische Anschluss darf nur von einer Fachkraft du...

Page 15: ...uch max 100W Sicherung F 3A 250VAC 5 x 20mm Best Nr FF3N Abmessungen 450 x 170 x 120mm Gesamtgewicht 3kg Lampe 12V 100W JDC G6 35 Best Nr LAMP100 12 Max Umgebungstemperatur 45 C Max Temperatur Geh use...