Figure 7: Button and Indicator panel
Item
Description
1
Pinhole button within
Power/Reset indicator
2
Power/Reset LED indicator
3
Active LED indicator
Momentarily press the pinhole button causes the appliance module to reboot, but does not reimage it.
After 10 seconds, the Active LED starts to flash, and the Power/Reset LED indicator turns amber, which means that
the reimage process was triggered.
6. Release the pinhole button as soon as you see the flashing Active LED.
If connected, the HPE Synergy Console shows progress messages. The front panel UID flashes blue throughout the
reimage process.
After reimaging, the appliance module reboots, updates the firmware to the version stored on the preloaded USB
drive, and starts oneview.mgmt.software. Reimaging is completed in approximately 90 minutes; at which time the
initial oneview.mgmt.software login screen appears in the HPE Synergy Console.
For Image Streamer, the administrator must log in to the appliance maintenance console, shut down the Image
Streamer and reseat it. Reseating the appliance module triggers the discovery, claim, and eventual cluster formation.
NOTE: During appliance module reimage, you might encounter the following message:
The appliance signature is not valid. Retry the reimage process with a USB
that contains a properly signed appliance image. The reimage of appliance
encountered errors and could not complete.
If you see this message, you must first reimage the appliance module to version 3.10.xx and then reimage to 4.0.xx.
7. Verify that the appliance module is reimaged by examining the firmware version number either on the Appliance
panel of the
Settings screen or by using the
View details
command of the appliance maintenance console.
8. Optionally, remove the preloaded USB flash drive and store it for possible future use.
Appliance management
43