Position
Default
Function
S6
Off
Off = No function
On = Restore default manufacturing settings
S7
Off
Reserved
S8
—
Reserved
S9
—
Reserved
S10
—
Reserved
S11
—
Reserved
S12
—
Reserved
To access the redundant ROM, set S1, S5, and S6 to On.
When the system maintenance switch position 6 is set to the On position, the system is prepared to restore all configuration settings to
their manufacturing defaults.
When the system maintenance switch position 6 is set to the On position and Secure Boot is enabled, some configurations cannot be
restored. For more information, see
DIMM slot locations
DIMM slots are numbered sequentially (1 through 16). The supported Advance Memory Protection (AMP) modes use the
letter assignments for population guidelines.
The arrow points to the front of the server.
DIMM label identification
To determine DIMM characteristics, see the label attached to the DIMM. The information in this section helps you to use
the label to locate specific information about the DIMM.
Component identification