16
3.
Orient the fan tray with the "TOP" mark on top. Grasp the handle of the fan tray and slide the fan
tray along the guide rails into the slot until the fan tray seats in the slot and the fan tray
connector has a firm contact with the backplane. See
Figure 19
.
Figure 19 Installing an HPE X712 HV2 fan tray in the HPE FlexFabric 5950 32QSFP28/HPE
FlexFabric 5950 32QSFP28 TAA switch
When the switch is powered on for the first time, use the
fan prefer-direction
command to configure
the airflow direction of the fan tray as the preferred airflow direction of the switch. If the fan tray
airflow direction and the preferred airflow direction are not the same, the system generates traps and
logs. By default, the preferred airflow direction is from the power module side to the port side.
For more information about the
fan prefer-direction
command, see
HPE FlexFabric 5950 Switch
Series Layer 2—LAN Switching Command References
.
Removing a fan tray
WARNING!
x
Ensure electricity safety and never touch the rotating fans when you hot-swap a fan tray.
x
To prevent a fan from causing loud noise, do not touch the fan blades and rotation axis, even if
the fan is not rotating.
To remove a fan tray:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Grasp the handle of the fan tray and pull the fan tray slowly out of the slot along the guide rails.
3.
Put the removed fan tray in an antistatic bag.
Figure 20 Removing an HPE X712 HV2 fan tray