background image

21 

4/28/2017                                                        860-EI 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 49X8SSEI-L

Page 1: ...ne or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If yo...

Page 2: ...ensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Spec...

Page 3: ...ng a safe distance from the heat and flame x IMPORTANT Deck Installation If installing fire pit on a wood or composite deck it is required to use the Deck Insulation Kit s and locally bought paver sto...

Page 4: ...Key Points x IMPORTANT The minimum requirement is the enclosure incorporate 1 vent on at least 2 sides 2 vents total at a minimum size of 18 sq inches of total free area each Example 3 x 6 or larger...

Page 5: ...nnections Repair as needed 4 Connect proper 110VAC or 24VAC electrical power following all local codes 5 Position fire pit safely with access to all gas connections for testing 6 Light fire pit It may...

Page 6: ...d resistance without coming loose 4 Bracket Attachment a Clip on the two nylon attachment brackets to the cable near the antenna Position the brackets based on the desired location to be attach to the...

Page 7: ...VER BURNER FOR CONFIRMATION OF NO BACK PRESSURE CREATING GAS TO LEAK OUT OF AIR MIXER VENTURI HOLES THIS MAY HAVE TO BE DONE PRIOR TO PLACING IN ENCLOSURE IF NO ACCESS DOOR x The fire pit is designed...

Page 8: ...flame opening 4 Blowout Box Do not cover blowout box vents or opening with lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner...

Page 9: ...l should be kept away from the fire pit Fire pit is not for cooking Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere with safe operatio...

Page 10: ...sitions e Remote Response Time When not in use for more than 30 seconds the remote will go into a sleep mode to save battery life If remote is in sleep mode it may take a few extra seconds for a comma...

Page 11: ...1 Download the HPC Fire App from the Apple store or Google Play 2 If power is already applied disconnect power for 20 seconds and reconnect power 3 Open the HPC Fire App see Fig 1 4 From the setup sc...

Page 12: ...lame HIGH LOW Timer amount of time left before shut off Troubleshoot Guide tap the link to online help Setup 1 Timer ON OFF and set the timer 2 Customize the fire pit s name 3 Customize the security c...

Page 13: ...es exhibit any abnormal shapes or behavior or if burner fails to ignite properly then the burner holes may require cleaning The appliance can be cleaned by carefully removing the logs and media to all...

Page 14: ...ied Media See Section 6 Main Burner Turning Off On Frequently 1 Small Pilot Flame Remove pilot head and clean orifice Section 8 2 Improperly applied Media See Section 6 3 Gas Pressure Improper Gas pre...

Page 15: ...15 4 28 2017 860 EI...

Page 16: ...16 4 28 2017 860 EI...

Page 17: ...17 4 28 2017 860 EI...

Page 18: ...couple 36 HSIP 36SS 300NG 300k Btu NG 312 HSIP SS 36 Hot Surface Igniter HSIP 36SS 400NG 400k Btu NG 312 EIMOD Control Module HSIP 36SS 50 225LP 50k 225k Btu LP 576 75VA Transformer HSIP 36SS 250 400L...

Page 19: ...PC FOB Dayton Ohio This warranty is for parts and in house HPC labor The defective product must be sent back to HPC with a Return Merchandise Authorization RMA issued by HPC for that specific product...

Page 20: ...20 4 28 2017 860 EI...

Page 21: ...21 4 28 2017 860 EI...

Page 22: ...22 4 28 2017 860 EI...

Page 23: ...23 4 28 2017 860 EI...

Reviews: