D–2
technical reference guide
Event, Error and Warning Messages
20
NVM token access error
—
21
BMC token write error during NVM write
through
—
22
Error reading BMC token on upload to
NVM
—
23
Error reading BMC first boot token
—
24
Primary FIT failed
Reflash firmware.
25
Secondary FIT failed
Reflash firmware.
26
PAL_A warning. One copy of PAL is bad
Reflash firmware.
27
PAL_B warning. Not compatible with CPU Update firmware.
28
Memory errors detected and PDT is
disabled
Reseat DIMMs. If error persists,
replace bad DIMM(s).
30
Memory required reinterleave to get a
good page 0
—
33
One or more memory ranks are
mismatched and deallocated
Load DIMMs in correct loading
order (page 2-12).
34
Memory deallocated because of a loading
error
Load DIMMs in correct loading
order (page 2-12).
35
Memory is not loaded recommended
loading order
Load DIMMs in correct loading
order (page 2-12).
36
The PDT is full
Clear with
pdt clear
command in
EFI shell.
37
At least one (1) CPU has bad fixed core
ratio
—
38
All CPUs were slated for compatibility
deconfig
—
42
All CPUs are over clocked
—
43
CPU is over clocked
—
44
Monarch changed to lowest stepping CPU Only seen once after monarch is
set to lowest stepping.
48
SAL NVM cleared
Information only, no action
required.
49
EFI NVM cleared
Information only, no action
required.
Error Number
Error/Warning Message
Solution