technical reference guide
D–1
D
event, error and warning messages
This appendix contains event, error and warning information for the zx2000 system, including:
■
EFI Error and Warning Messages
■
IPMI Event Messages
■
Sensor Data Record Repository (SDRR)
EFI error and warning messages
EFI error and warning messages are displayed on the console as part of the boot process. They
can also be retrieved via the
info warnings
EFI command.
.
Error Number
Error/Warning Message
Solution
2
Insufficient resources to assign to one or
more I/O devices
—
3
Failed I/O socket(s) deconfiguration
—
4
Unexpected hardware I/O configuration
—
7
No BMC installed in platform
Ensure the BMC ROM is installed;
update BMC firmware.
8
BMC cannot be accessed
Check BMC logs for errors.
9
One or more BMC ports failed
—
10
BMC system event log is full
Clear SEL.
11
Platform SCR is bad
Call support center.
12
Set time to BMC SEL failed
—
13
SEL get info failed
—
14
Initial BMC SEL event failed
—
15
Update of BMC buffered data failed
—
16
All ACPI BMC ports bad
—
17
Read error on BMC token
—
18
BMC token transmit checksum error
—
19
Error writing BMC token on download
—