9
Checking the SCSI connection
Use the following questions to help you check your SCSI connection. As long as you have a
spare drive bay in your server you should have a spare connection on the internal SCSI bus.
You need to ensure it is the correct SCSI bus type. If you answer ‘Yes’ to all these questions,
you are ready to install your tape drive. If you answer ‘No’, you will probably need to
purchase and install additional items. For compatibility and product details, go to
www.hp.com/go/connect
.
table 1: supported SCSI bus types
SCSI Bus Type
Supported
Ultra wide LVD
Yes.
This is a
recommended
configuration as long as the drive is
the only device on the SCSI bus.
Ultra 2 LVD, Ultra 3 (160) LVD,
Ultra 4 (320) LVD
Yes.
These are
recommended
configurations, particularly if there
are several devices on the SCSI bus.
Ultra wide, single-ended
Yes. But this is
not
a recommended configuration as it will restrict
performance.
Ultra narrow, single-ended
Yes.
But this is
not
recommended as it will severely restrict
performance and you will need a suitable cable or adapter.
High Voltage Differential
No.
The drive will not work and you may damage the drive or
controller
1
Have you checked the SCSI
bus type and SCSI IDs in use?
4
You are ready to install the
drive.
3
Will the drive be the only
device on the bus? This is the
recommended configuration.
Do
not
connect to a RAID
controller or the same SCSI
bus as your disk drive.
2
Is the SCSI bus type correct
for the SCSI specification of
the drive?
See table below. If the SCSI bus differs from
the recommended specification for the drive,
performance of either the drive or the bus may
be impaired. Consider replacing your card
with one of the recommended HBAs.
Users of most operating systems can use HP
Library & Tape Tools to do this. The SCSI
topic in the online User’s Guide provides
further advice on identifying SCSI IDs.
If you have an Ultra HBA, performance may
be impaired. Consider installing (if you have
a spare PCI slot) or replacing your card with
an Ultra 2, Ultra 3 (160) or Ultra 4 (320)
HBA.
Yes
Yes
Yes
No
No
No
dds-internal-frame6.fm Page 9 Monday, January 5, 2004 5:01 PM
Summary of Contents for StorageWorks DAT 40i
Page 1: ...getting started guide hp StorageWorks DAT tape drive internal model DAT 40i DAT 72i ...
Page 2: ...open this flap for quick start installation poster ...
Page 3: ...5 1 4 ...
Page 4: ...2 3 6 7 UNIX ...
Page 14: ...10 2 4 1 8 NC TP 2 4 1 8 NC TP 2 4 1 8 NC TP 3 DEFAULT 6 11 Figure 3 checking the SCSI ID ...
Page 16: ...12 Figure 4 setting the UNIX configuration switches ...
Page 22: ...18 Figure 7 installing the drive power cable extension ...
Page 36: ...32 Figure 13a hp obdr step 1 Figure 13b hp obdr step 2 Figure 13c hp obdr step 3 ...
Page 49: ......
Page 50: ...http www hp com go storagemedia http www hp com support dat Printed in the UK C5686 90906 ...