94
Troubleshooting
Messages identify five levels of severity:
Event messages (see Figure 54) contain the following:
■
Message Data – Date and time the message was sent, the source and
destination of the message, and the severity level
■
Event Data – Date and time of the event, the host, event ID, name of the
monitor, event number, event class, severity level, hardware path, associated
OS error log entry ID
■
Error Description – Narrative information indicating the component that
experienced the event and the nature of the event
■
Probable Cause/Recommended Action – The cause of the event and
suggested steps toward a solution. This information should be the first step in
troubleshooting.
■
Annotation – The user-defined annotation associated with the specific disk
system
Critical
An event that causes data loss, host system downtime,
or other loss of service. Host system operation will be
affected if the disk system continues to be used without
correction. Immediate action is required.
Serious
An event that may cause data loss, host system
downtime, or other loss of service if left uncorrected.
Host system and hardware operation may be adversely
affected. The problem needs repair as soon as possible.
Major Warning
An event that could escalate to a serious condition if
not corrected. Host system operation should not be
affected and normal use of the disk system can
continue. Repair is needed but at a convenient time.
Minor Warning
An event that will not likely escalate to a severe
condition if left uncorrected. Host system operation
will not be interrupted and normal use of the disk
system can continue. The problem can be repaired
when convenient.
Information
An event that is expected as part of the normal
operation of the hardware. No action is required.
Summary of Contents for StorageWorks 2405 - Disk System
Page 1: ...hp StorageWorks disk system 2405 Edition E0902 user s guide ...
Page 3: ...Revision History First Edition March 2002 Second Edition June 2002 Third Edition Sept 2002 ...
Page 4: ......
Page 12: ...12 ...
Page 14: ......
Page 18: ......
Page 30: ...30 Product Description ...
Page 35: ......
Page 36: ......
Page 40: ...40 Installation 3 If a part is missing contact an HP sales representative ...
Page 44: ......
Page 47: ...Installation 47 Installation ...
Page 51: ......
Page 55: ...Installation 55 Installation 10 Install a filler panel in the space below the storage device ...
Page 57: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 73: ......
Page 74: ......
Page 77: ......
Page 80: ...80 Installation ...
Page 108: ...108 Troubleshooting ...
Page 128: ......
Page 138: ...138 Reference E VCCI Statement Japan Harmonics Conformance Japan F BSMI EMC Statement Taiwan ...
Page 139: ...Reference 139 Reference G Declaration of Conformity ...