Table 3 Port side LED patterns
Recommended action
Status of hardware
LED color
LED name
Verify that the system is powered on (power
supply switches set to I), the power cables
are attached, and the power source is live.
System is off or there is an internal
power supply failure.
No light
System power
(green)
The unit may be faulty. Contact your switch
service provider.
No action required
System is on and power supplies are
functioning properly.
Steady green
Verify that the system is on and has
completed booting
System is off or there is no power.
No light
System status
(bicolor)
No action required.
System is on and functioning
properly.
Steady green
Check the failure indicated on the system
console.
A system fault has occurred. This LED
is steady amber during POST, which
Steady amber
(for more than 5
seconds)
Contact your switch service provider.
is normal and does not indicate a
fault.
Check the management interface and the
error log for details on the cause of status.
Attention is required. A number of
variables can cause this status,
Blinking amber
Contact your switch service provider.
including a single power supply
failure, a fan failure, or one or more
environmental ranges exceeded.
Verify that the Ethernet cable is connected
correctly.
There is no link.
No light
Ethernet port
activity/link
No action required
There is a link.
Steady green
No action required
There is link activity (traffic).
Blinking green
No action required
Port speed is 10 Mb/s.
No light
Ethernet port
speed
No action required
Port speed is 100 Mb/s.
Steady green
Verify that the transceiver is installed
correctly and that the cable is connected
correctly.
No light or signal carrier on media
interface
Off
FC optical
media port
status (one
bicolor LED for
each FC port)
No action required
Receiving light or carrier, but not
online
Steady amber
Verify that the diagnostic tests are not being
run. Re-enable the port using the
portenable
command.
Disabled (by diagnostics or by
portdisable
command).
Slow blinking
amber (2
seconds)
Check the management interface and the
error log for details on the cause of the
Port failure
Fast blinking
amber (1/2
second)
failure. Contact technical support if
necessary.
No action required
Online
Steady green
No action required
Online but segmented (loopback
cable or incompatible switch)
Slow blinking
green (2 seconds)
No action required
Internal loopback (diagnostic)
Fast blinking
green (1/2
second)
No action required
Online, frames flowing through port
Flickering green
The nonport side of the switch has one LED per power supply/fan assembly. See
Figure 15 (page
30)
.
Table 4 (page 30)
describes the status.
LEDs
29
Summary of Contents for SN6000B
Page 48: ...French laser notice German laser notice Italian laser notice 48 Regulatory compliance notices ...
Page 54: ...French battery notice German battery notice 54 Regulatory compliance notices ...
Page 55: ...Italian battery notice Japanese battery notice Battery replacement notices 55 ...
Page 56: ...Spanish battery notice 56 Regulatory compliance notices ...
Page 59: ...WWN World Wide Name 59 ...