2.
Select Serial Port.
3.
Select Com1.
4.
Check the settings and change, if required.
Go to More Settings to set Xon/Xoff. Click OK to close the More Settings window.
5.
Click OK to close the Connection Setup window.
6.
Pull down the Setup menu and select Terminal (under the Emulation tab).
7.
Select terminal type VT100.
8.
Click Apply.
This option is not highlighted if the terminal type you want is already selected.
9.
Click OK.
Connecting the CE Tool to the Local RS-232 Port on the MP
This connection allows direct communications with the MP. Only one window can be created
on the CE Tool to monitor the MP. When enabled, it provides direct access to the MP and any
partition.
To connect the CE Tool to the Local RS-232 port on the MP, follow these steps:
1.
Connect one end of a null modem cable (9-pin to 9-pin) (Part Number 5182-4794) to the M
cable connector labeled CONSOLE.
2.
Connect the other end of the RS-232 cable to the CE Tool.
Standby Power and Logging In to the MP
After connecting the serial device, it is possible to log in to the Management Processor (MP).
Housekeeping power (also known as standby power) is generated as soon as AC power is applied
to the server. Because the MP uses standby power, it is possible to log in to the MP even when
the power switch is in the OFF position. The power switch is a DC power switch that controls
+48 V DC.
Before powering up the HP 9000 rp7420 server for the first time, follow these steps:
1.
Verify that the AC voltage at the input source is within specifications for each server being
installed.
2.
If not already done so, power on the serial display device.
The preferred tool is the CE Tool running Reflection.
To power up the MP, set up a communications link, and log in to the MP, follow these steps:
1.
Connect the server to AC power.
On the front of the HP 9000 rp7420 server, a solid green Standby Power LED, a solid green
MP Present LED, and a flashing amber Attention LED illuminate after about 30 seconds.
Figure 4-6 Front Panel Display
2.
Check the bulk power supply LED for each BPS.
When on, the breakers distribute power to the BPSs. AC power is present at the BPSs:
MP Core I/O Connections
57
Summary of Contents for rp7420
Page 3: ......
Page 4: ......
Page 12: ...12 ...
Page 16: ...16 ...
Page 30: ...Figure 1 12 Left Rear View of HP 9000 rp7420 server 30 Overview ...
Page 40: ...40 ...
Page 50: ...50 ...
Page 82: ...82 ...
Page 108: ...108 ...
Page 119: ...Figure D 3 Planning Grid Computer Room Layout Plan 119 ...
Page 120: ...Figure D 4 Planning Grid 120 Site Preparation Guidelines ...
Page 121: ...Figure D 5 Planning Grid Computer Room Layout Plan 121 ...
Page 122: ...Figure D 6 Planning Grid 122 Site Preparation Guidelines ...
Page 123: ...Figure D 7 Planning Grid Computer Room Layout Plan 123 ...
Page 124: ...124 ...
Page 127: ...X XD 115 127 ...