Standard Operation Procedure
Tabulator
:
Issue Department
:
Xin-Xin Chen
NPSU-PPE
Auditor
:
Ethan Lai
Steps
:
Document No. : Pyxis400
DISASS’Y SOP Station :
Operation Name : Ver. :
Date :
Note: If finding anything uncommon, notice foreman or assistant at once.
Fixture list (Specification)
Qty.
Fixture list (Specification)
Qty.
3(1/1)
2017/5/23
1.00
Glove Requirements: Full-fingered gloves
Electric Screwdriver (S-6000MS)
Take out M/B shielding
Fig. 1
1. Unscrew (Torx Pin-Head
×
4) all joints to take
out M/B shielding (Fig. 1).
Torsion: 4.0
±
1.0 kgf.cm
Take the screwdriver vertically to the screw
holes.
The screw holes are marked in red circles.