To replace the component, reverse the removal procedure.
Enabling the dedicated iLO management module
Procedure
1.
During the server startup sequence after installing the module, press
F9
in the POST screen.
The System Utilities screen appears.
2.
Select
System Configuration
|
iLO 4 Configuration Utility
.
The iLO 4 Configuration Utility screen appears.
3.
Select
Network Options
, and then press
Enter
.
The Network Options screen appears.
4.
Set the
Network Interface Adapter
field to
ON
, and then press
Enter
.
5.
Press
F10
to save your changes.
A message prompt to confirm the iLO settings reset appears.
6.
Press
Enter
to reboot the iLO settings.
7.
Press
Esc
until the main menu is displayed.
8.
Select
Reboot the System
to exit the utility and resume the boot process.
The IP address of the enabled dedicated iLO connector appears on the POST screen on the
subsequent boot-up. Access the Network Options screen again to view this IP address for later
reference.
Heatsink
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
Enabling the dedicated iLO management module
69
Summary of Contents for ProLiant XL270d Gen9
Page 12: ...12 Customer self repair ...
Page 13: ...Customer self repair 13 ...
Page 14: ...14 Customer self repair ...
Page 15: ...Customer self repair 15 ...
Page 118: ... Slot 10 118 Cabling ...
Page 120: ...PCI riser module signal cabling 4 1 riser signal cable 120 PCI riser module signal cabling ...
Page 121: ...8 1 riser sideband cable 8 1 riser sideband cable 121 ...