![HP ProLiant ML350p Gen8 Maintenance And Service Manual Download Page 42](http://html.mh-extra.com/html/hp/proliant-ml350p-gen8/proliant-ml350p-gen8_maintenance-and-service-manual_164880042.webp)
Removal and replacement procedures 42
2.
Power down the server (on page
26
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page
28
).
5.
Access the product rear panel.
6.
Remove all power supply modules from the power supply cage ("
Power supply module
" on page
41
).
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
7.
Remove the screws, and slide the power supply cage out of the server:
o
Two-bay power supply configuration
Summary of Contents for ProLiant ML350p Gen8
Page 12: ...Customer self repair 12 ...
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 23: ...Illustrated parts catalog 23 ...